Table 21. Sensor information, event description, and service action for the 8335-GCA and 8335-GTA
Sensor name (Sensor ID)
Event description
Service action
Watchdog (0x00)
v
Timer Expired
v
Reserved1
v
Reserved2
v
Reserved3
v
Reserved4
No service action is required.
v
Hard Reset
v
Power Down
v
Power Cycle
v
Timer Interrupt
SEL events with OEM record c0 |
000e000 | 3a150
xxxxxxx indicate that
a boot failed. Search for boot failure
SEL events that have a time stamp in
close proximity to the time stamp of
this SEL event. If events exist, go to
“Resolving a system firmware boot
failure” on page 4. If there are no
boot failure SEL events and the
system booted correctly, no service
action is required.
Host Status (0x04)
Unknown
Go to Getting fixes and update the
system firmware to the most recent
level of firmware that is available. If
this SEL event continues to be logged
each time you power on the system,
go to “Collecting diagnostic data” on
page 109. Then, go to “Contacting
IBM service and support” on page
110.
v
S0/Go “Working”
v
S1 “Sleeping with system h/w &
processor context maintained”
v
S2 “sleeping, processor context
lost”
v
S3 “sleeping, processor & h/w
context lost, memory retained”
v
S4 “non-volatile sleep / suspend-to
disk”
v
S5 / G2: “soft-off”
v
S4 / S5: “soft-off”
v
G3 mechanical Off
v
Sleeping in an S1/S2/S3 State
v
G1: Sleeping
v
S5: entered by override
v
Legacy ON state
v
Legacy OFF state
No service action is required.
38
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C