![IBM Power System 8335-GCA Manual Download Page 44](http://html.mh-extra.com/html/ibm/power-system-8335-gca/power-system-8335-gca_manual_607961044.webp)
v
To list SELs by using an in-band network, use the following command:
ipmitool sel elist
v
To list SELs remotely over the LAN, use the following command:
ipmitool -I lanplus -U <username> -P <password> -H <BMC IP addres or BMC hostname> sel elist
2.
Scan the SELs for an event with the value
OEM record de
. Did you find a SEL with the value
OEM
record de
?
If
Then
Yes:
Continue with the next step.
No
Go to step 4 on page 29.
3.
The OEM record de specific log information is indicated by the rightmost digits of the SEL with the
value
OEM record de
. Use Table 17 to determine the service action to perform.
Table 17. OEM record de specific log information and service action
OEM record de specific log information
Service action
00xxxxxxxxxx
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to “Collecting
diagnostic data” on page 109. Then, go to “Contacting
IBM service and support” on page 110.
01xxxxxxxxxx
Go to the “EPUB_PRC_FIND_DECONFIGURE_PART
isolation procedure” on page 96.
04xxxxxxxxxx
Go to the “EPUB_PRC_SP_CODE isolation procedure”
on page 97.
05xxxxxxxxxx
Go to the “EPUB_PRC_PHYP_CODE isolation
procedure” on page 97.
08xxxxxxxxxx
Go to the “EPUB_PRC_ALL_PROCS isolation procedure”
on page 98.
09xxxxxxxxxx
Go to the “EPUB_PRC_ALL_MEMCRDS isolation
procedure” on page 98.
0Axxxxxxxxxx
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to “Collecting
diagnostic data” on page 109. Then, go to “Contacting
IBM service and support” on page 110.
10xxxxxxxxxx
Go to the “EPUB_PRC_LVL_SUPPORT isolation
procedure” on page 99.
16xxxxxxxxxx
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to “Collecting
diagnostic data” on page 109. Then, go to “Contacting
IBM service and support” on page 110.
1Cxxxxxxxxxx
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to “Collecting
diagnostic data” on page 109. Then, go to “Contacting
IBM service and support” on page 110.
22xxxxxxxxxx
Go to the “EPUB_PRC_MEMORY_PLUGGING_ERROR
isolation procedure” on page 100.
2Dxxxxxxxxxx
Go to the “EPUB_PRC_FSI_PATH isolation procedure”
on page 100.
28
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Summary of Contents for Power System 8335-GCA
Page 2: ......
Page 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Page 173: ......
Page 174: ...IBM ...