![IBM Power System 8335-GCA Manual Download Page 48](http://html.mh-extra.com/html/ibm/power-system-8335-gca/power-system-8335-gca_manual_607961048.webp)
Table 18. OEM record c0 specific log information, description, and service action for an 8335-GCA or
8335-GTA (continued)
OEM record c0 specific log
information
Description
Service action
3a1603xxxxxx
Fan 3 failure
Replace Fan 3. Go to “8335-GCA and
8335-GTA locations” on page 111 to
identify the physical location and
removal and replacement procedure.
3a1604xxxxxx
Fan 4 failure
Replace Fan 4. Go to “8335-GCA and
8335-GTA locations” on page 111 to
identify the physical location and
removal and replacement procedure.
3a260xyyyyyy, where x = 1, 2, or 3
System shut down due to one or
more missing or failed fans
The OEM record c0 specific log
information is 3a260xyyyyyy, where x
is the number of fans that were
missing or failed when the system
was shut down. The system cannot
be powered on with missing fans. If
any SEL events were logged with
OEM record c0 specific log
information 3a16xxxxxxxx, complete
the service action indicated in this
table. Otherwise, replace the fans,
one at a time, until the problem is
resolved. Go to “8335-GCA and
8335-GTA locations” on page 111 to
identify the physical location and
removal and replacement procedure.
3a2604yyyyyy
All of the fans are missing or failed
Ensure that the fan power cable and
the disk and fan signal cable are
seated properly. If the problem
persists, replace the following items,
one at a time, until the problem is
resolved:
Note:
8335-GTA locations” on page 111 to
identify the physical location and
removal and replacement procedure.
v
Power riser with time-of-day
battery slot
v
Fan power cable
v
Disk and fan signal cable
v
Disk drive and fan card
Table 19. OEM record c0 specific log information, description, and service action for an 8335-GTB
OEM record c0 specific log
information
Description
Service action
320a01xxxxxx
Phy read failure
If you are viewing this event from
the BMC, the missing or defective
cable is now operational and no
service action is required. Otherwise,
replace the missing or failed LAN
cable that attaches the console to the
system.
320a02xxxxxx
Phy speed and duplex failure
32