EPUB_PRC_MEMORY_PLUGGING_ERROR isolation procedure
Memory DIMMs are plugged in a configuration that is not valid.
v
If your system is an 8335-GCA or 8335-GTA, go to Plugging rules for memory in the 8335-GCA system.
v
If your system is an 8335-GTB, go to Plugging rules for memory in the 8335-GTB system.
v
If your system is an 8348-21C, go to Placement rules for memory in the 8348-21C system.
This ends the procedure.
EPUB_PRC_FSI_PATH isolation procedure
The system detected an error with the FSI path.
Use the following table to determine the service action:
Table 25. EPUB_PRC_FSI_PATH service actions
System
Service action
8335-GCA or 8335-GTA
Replace the following items, one at a time, in the order
that is shown until the problem is resolved:
1.
System processor CPU 1
2.
System processor CPU 2
3.
System backplane
Go to “8335-GCA and 8335-GTA locations” on page 111
to identify the physical location and removal and
replacement procedure. If the replacement of the system
processors and the system backplane does not resolve the
problem, go to “Contacting IBM service and support” on
page 110. This ends the procedure.
8335-GTB
Replace the following items, one at a time, in the order
that is shown until the problem is resolved:
1.
System processor CPU 1
2.
System processor CPU 2
3.
System backplane
Go to “8335-GTB locations” on page 121 to identify the
physical location and removal and replacement
procedure. If the replacement of the system processors
and the system backplane does not resolve the problem,
go to “Contacting IBM service and support” on page 110.
This ends the procedure.
8348-21C
Replace the following items, one at a time, in the order
that is shown until the problem is resolved:
1.
System processor
2.
System backplane
Go to “8348-21C locations” on page 133 to identify the
physical location and removal and replacement
procedure. If the replacement of the system processor
and the system backplane does not resolve the problem,
go to “Contacting IBM service and support” on page 110.
This ends the procedure.