e.
Complete the following steps to cable a configuration that includes two hard-disk-drive partitions,
nine disks per hard-disk-drive partition, and two SAS adapters.
Note:
You must have a minimum of one disk drive per hard-disk-drive partition.
1)
Set the hard-disk-drive partitions switch to position 2. The hard-disk-drive partitions switch is
located at the rear of the 5802 expansion unit, just below the SAS connectors.
2)
Choose one of the following SAS adapter and cable combination options:
v
Two FC ESA1 adapters (PCIe2 RAID SAS Dual-port 6 Gb) cabled with two FC 3689 cables
(AT 0.6 meter - HD SAS)
v
Two FC 5901 adapters (PCIe Dual - x4 SAS) cabled with two FC 3688 cables (AT 0.6 meter -
Mini SAS)
3)
Attach an AT cable
(B)
from one port on one SAS adapter
(A)
to SAS connector 1 on the 5802
SAS conduit card
(C)
, as shown in the following figure.
4)
Attach an AT cable
(B)
from one port on the other SAS adapter
(A)
to SAS connector 3 on the
5802 SAS conduit card
(C)
.
5)
Optional: Use other ports on the same SAS adapters to connect a 5886 disk drive enclosure or
5887 disk drive enclosure by using SAS YO cables
(D)
.
6)
Go to step 1i on page 25.
f.
Complete the following steps to cable a configuration that includes two hard-disk-drive partitions,
nine disks per hard-disk-drive partition, a dual SAS adapter pair per hard-disk-drive partition that
controls the disks in the partition, and dual SAS connectivity to all drives.
Notes:
v
For the following operating systems, this configuration must be a RAID configuration: AIX,
Linux
v
You must have a minimum of one disk drive per hard-disk-drive partition.
1)
Set the hard-disk-drive partitions switch to position 2. The hard-disk-drive partitions switch is
located at the rear of the 5802 expansion unit, just below the SAS connectors.
2)
Choose one of the following SAS adapter and cable combination options:
v
Four FC ESA1 adapters (PCIe2 RAID SAS Dual-port 6 Gb) cabled with four FC 3689 cables
(AT 0.6 meter - HD SAS)
v
Four FC 5805 or FC 5903 adapters (PCIe Dual - x4 3 Gb SAS RAID) cabled with four FC 3688
cables (AT 0.6 meter - Mini SAS)
v
Four FC 5901 adapters (PCIe Dual - x4 SAS) cabled with four FC 3688 cables (AT 0.6 meter -
Mini SAS)
Figure 19. Configuration with two hard-disk-drive partitions and two SAS adapters
22
Power Systems: Installing the 5802 and 5877 expansion units
Summary of Contents for Power System 5802
Page 1: ...Power Systems Installing the 5802 and 5877 expansion units GI11 4307 09...
Page 2: ......
Page 3: ...Power Systems Installing the 5802 and 5877 expansion units GI11 4307 09...
Page 6: ...iv Power Systems Installing the 5802 and 5877 expansion units...
Page 38: ...26 Power Systems Installing the 5802 and 5877 expansion units...
Page 52: ...40 Power Systems Installing the 5802 and 5877 expansion units...
Page 62: ...50 Power Systems Installing the 5802 and 5877 expansion units...
Page 63: ......
Page 64: ...Part Number 00L5079 Printed in USA GI11 4307 09 1P P N 00L5079...