BCS
ECS
Explanation and possible recovery action
07
2C
Explanation:Online/Rebuild and Ready/Standby drives are not responding, and a drive was
found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
38
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding.
Action:Press F4, F5, or F10.
07
3C
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, and a drive was found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
48
Explanation:Online/Rebuild drives are not responding, and unidentified drives were found.
Action:Press F4, F5, or F10.
07
4C
Explanation:Online/Rebuild drives are not responding, and a drive was found at the incorrect
SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
58
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, and
unidentified drives were found.
Action:Press F4, F5, or F10.
07
5C
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, a
drive was found at the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
68
Explanation:Online/Rebuild and Ready/Standby drives are not responding, and unidentified
drives were found.
Action:Press F4, F5, or F10.
07
6C
Explanation:Online/Rebuild and Ready/Standby drives are not responding, a drive was found at
the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
07
78
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, and unidentified drives were found.
Action:Press F4, F5, or F10.
07
7C
Explanation:Online/Rebuild, Ready/Standby, and Hot-Spare/Standby Hot-Spare drives are not
responding, a drive was found at the incorrect SCSI ID, and unidentified drives were found.
Action:Press F4, F5, F6, or F10.
09
00
Explanation:No error occurred.
Action:No action is required.
09
10
Explanation:Hot-Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, or F10.
09
20
Explanation:Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
09
30
Explanation:Hot-Spare/Standby Hot-Spare and Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
66
IBM
®
Netfinity
®
: ServeRAID
™
-4L Ultra160 SCSI Controller User’s Reference
Summary of Contents for Netfinity ServeRAID-4L Ultra160
Page 1: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 2: ......
Page 3: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 12: ...x IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 15: ...Part 1 Installation and configuration Copyright IBM Corp 2000 1...
Page 16: ...2 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 34: ...20 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 50: ...36 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 51: ...Part 2 Utility programs Copyright IBM Corp 2000 37...
Page 52: ...38 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 56: ...42 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 64: ...50 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 68: ...54 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 69: ...Part 3 Maintenance and troubleshooting Copyright IBM Corp 2000 55...
Page 70: ...56 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 93: ...Part 4 Appendixes Copyright IBM Corp 2000 79...
Page 94: ...80 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 113: ......