BCS
ECS
Explanation and possible recovery action
03
B8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
03
C8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
D8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild and Hot-Spare/Standby Hot-Spare drives are not responding and unidentified
drives were found.
Action:Press F4, F5, F7, or F10.
03
E8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild and Ready/Standby drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
F8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and Ready/Standby drives are not responding
and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
07
00
Explanation:The specified drive is not responding.
Action: To correct the problem:
1. If the specified physical drive is in an external enclosure, check to make sure the enclosure
is powered on. If the enclosure is not powered on, turn on the power and press F4 to retry.
2. Download and install the latest version of IBM ServeRAID software. See “Obtaining
ServeRAID updates” on page 21 for more information.
3. Replace the failed physical drive.
07
08
Explanation:The specified drives are not responding.
Action: To correct the problem:
1. If the specified physical drives are in an external enclosure, check to make sure the
enclosure is powered on. If the enclosure is not powered on, turn on the power and press F4
to retry.
2. Download and install the latest version of IBM ServeRAID software. See “Obtaining
ServeRAID updates” on page 21 for more information.
3. Replace the failed physical drives.
07
0C
Explanation:Online/Rebuild drives are not responding, and a drive was found at the incorrect
SCSI ID.
Action:Press F4, F5, F6, or F10.
07
18
Explanation:Online/Rebuild and Hot-Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, or F10.
07
1C
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
28
Explanation:Online/Rebuild and Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
Chapter 9. Solving ServeRAID problems
65
Summary of Contents for Netfinity ServeRAID-4L Ultra160
Page 1: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 2: ......
Page 3: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 12: ...x IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 15: ...Part 1 Installation and configuration Copyright IBM Corp 2000 1...
Page 16: ...2 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 34: ...20 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 50: ...36 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 51: ...Part 2 Utility programs Copyright IBM Corp 2000 37...
Page 52: ...38 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 56: ...42 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 64: ...50 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 68: ...54 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 69: ...Part 3 Maintenance and troubleshooting Copyright IBM Corp 2000 55...
Page 70: ...56 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 93: ...Part 4 Appendixes Copyright IBM Corp 2000 79...
Page 94: ...80 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 113: ......