Installing the server in a rack cabinet
Important:
Review the documentation that comes with your rack enclosure for safety and cabling considerations.
When installing your server in a rack, the following considerations should be made:
The server should be installed in a maximum 35 degree C environment
To ensure proper air flow, it is recommended that the air vents not be blocked, usually 15 cm (6 in.) of
air space is sufficient
To ensure stability, precautions should be taken to prevent uneven loading of the rack; loading of the
rack should begin at the bottom
When multiple components are installed in a rack, precautions should be taken to prevent overloading
of power outlets
The server should always be connected to a properly grounded outlet
Use the following basic steps to install your server in a rack cabinet:
1.
Refer to your server and rack documentation for detailed installation information.
Note:
Removing rack doors and side panels makes it easier to install the server.
2.
Use the rack installation template that comes with the 5Ux24D Tower-to-Rack Kit to mark the holes on
your rack cabinet for cage nut or clip nut, according to your rack installation.
Note:
The rack installation template contains full instructions to complete server installation. Steps
are repeated here in case your template is not available. See Figure 19 on page 15 for cage
nut or clip nut locations on the front (release latch retaining screws
C
and slide rails
D
) and
rear (cable-management arm hinge bracket
B
and slide rails
A
) of your rack.
14
Copyright IBM Corp. 2000
Summary of Contents for Netfinity 5Ux24D Tower-to-Rack Kit
Page 1: ...IBM IBM Netfinity 5Ux24D Tower to Rack Kit Installation Instructions ...
Page 2: ......
Page 3: ...IBM IBM Netfinity 5Ux24D Tower to Rack Kit Installation Instructions ...
Page 8: ...vi 5Ux24D Tower to Rack Kit Installation Instructions ...
Page 37: ......
Page 38: ...IBM Part Number 19K0825 Printed in U S A 19K 825 ...