SCSI
error
codes
Error
code
FRU/action
All
SCSI
Errors
One
or
more
of
the
following
problems
might
be
causing
the
error:
v
A
failing
SCSI
device
(adapter,
drive,
controller)
v
An
improper
SCSI
configuration
or
SCSI
termination
jumper
setting
v
Duplicate
SCSI
IDs
in
the
same
SCSI
chain
v
A
missing
or
improperly
installed
SCSI
terminator
v
A
defective
SCSI
terminator
v
An
improperly
installed
cable
v
A
defective
cable
1.
Make
sure
that
external
SCSI
devices
are
turned
on
before
you
turn
on
the
computer.
2.
Make
sure
that
the
cables
for
all
external
SCSI
devices
are
connected
correctly.
3.
If
you
have
attached
an
external
SCSI
device
to
the
computer,
make
sure
the
external
SCSI
termination
is
set
to
automatic.
4.
Make
sure
that
the
last
device
in
each
SCSI
chain
is
terminated
correctly.
5.
Make
sure
that
the
SCSI
devices
are
configured
correctly.
Temperature
error
messages
Message
Action
DASD
Over
Temperature
(level-critical;
direct
access
storage
device
bay
x
was
over
temperature)
v
Make
sure
that
the
computer
is
being
properly
cooled
;
see
“System
reliability
guidelines”
on
page
29.
DASD
Over
recommended
Temperature
(sensor
x
)
(level-warning;
DASD
bay
x
had
over
temperature
condition)
v
Make
sure
that
the
computer
is
being
properly
cooled
;
see
“System
reliability
guidelines”
on
page
29.
DASD
under
recommended
temperature
(sensor
x
)
(level-warning;
direct
access
storage
device
bay
x
had
under
temperature
condition)
v
Ambient
temperature
must
be
within
normal
operating
specifications
;
see
“Features
and
specifications”
on
page
3.
DASD
Over
Temperature
(level-critical;
sensor
for
DASD1
reported
temperature
over
recommended
range)
v
Make
sure
that
the
computer
is
being
properly
cooled
;
see
“System
reliability
guidelines”
on
page
29.
Power
supply
x
Temperature
Fault
(level-critical;
power
supply
x
had
over
temperature
condition)
1.
Make
sure
that
the
computer
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
29.
2.
Replace
power
supply
x
System
board
is
over
recommended
temperature
(level-warning;
system
board
is
over
recommended
temperature)
1.
Make
sure
that
the
computer
is
being
properly
cooled
;
see
“System
reliability
guidelines”
on
page
29.
2.
Replace
the
system
board.
System
board
is
under
recommended
temperature
(level-warning;
system
board
is
under
recommended
temperature)
v
Ambient
temperature
must
be
within
normal
operating
specifications
;
see
“Features
and
specifications”
on
page
3.
System
over
temperature
for
CPU
x
(level-warning;
CPU
x
reporting
over
temperature
condition)
v
Ensure
system
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
29.
98
IntelliStation
M
Pro
Types
6225
and
6228:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for IntelliStation M Pro 6225
Page 1: ...IntelliStation M Pro Types 6225 and 6228 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...IntelliStation M Pro Types 6225 and 6228 Hardware Maintenance Manual and Troubleshooting Guide...
Page 135: ...Appendix B Safety information 125...
Page 137: ...Appendix B Safety information 127...
Page 139: ...Appendix B Safety information 129...
Page 141: ...Appendix B Safety information 131...
Page 151: ...Appendix B Safety information 141...
Page 153: ...Appendix B Safety information 143...
Page 155: ...Appendix B Safety information 145...
Page 175: ......
Page 176: ...Part Number 25K8120 Printed in USA 1P P N 25K8120...