Code
Function
Result
Text
message
Action
301
Keyboard
Failed
On
system-board
keyboard
test
failed
1.
Make
sure
that
the
keyboard
cable
is
connected
to
the
correct
port
(for
example,
make
sure
that
it
is
not
connected
to
the
mouse
port).
2.
If
the
problem
remains,
replace
the
keyboard
cable.
3.
Replace
the
keyboard.
4.
Call
for
service.
302
Mouse
Failed
On
system-board
pointing
device
test
failed.
1.
Make
sure
that
the
pointing
device
(mouse)
cable
is
correctly
connected
to
the
correct
port.
2.
Replace
the
pointing
device.
3.
Call
for
service.
305
Video
monitor
Any
message
See
the
information
that
came
with
the
monitor.
405
Ethernet
Failed
In
PCI-X
slot
n
(where
n
is
the
PCI-X
slot
number
in
which
the
failing
Ethernet
adapter
is
installed)
1.
Replace
the
Ethernet
adapter
in
slot
n.
2.
If
the
problem
remains,
call
for
service.
On
system
board
1.
Use
the
Configuration/Setup
Utility
program
to
make
sure
that
the
Ethernet
adapter
is
not
disabled.
2.
Call
for
service.
415
Modem
Failed
Any
failure
message
1.
Make
sure
that
the
modem
is
present
and
correctly
connected
to
the
computer.
2.
Replace
the
modem
cable.
3.
Replace
the
modem.
4.
Call
for
service.
Chapter
5.
Solving
problems
85
Summary of Contents for IntelliStation A Pro 6224
Page 1: ...IntelliStation A Pro Type 6224 User s Guide...
Page 2: ......
Page 3: ...IntelliStation A Pro Type 6224 User s Guide...
Page 8: ...vi IntelliStation A Pro Type 6224 User s Guide...
Page 22: ...8 IntelliStation A Pro Type 6224 User s Guide...
Page 46: ...32 IntelliStation A Pro Type 6224 User s Guide...
Page 124: ...110 IntelliStation A Pro Type 6224 User s Guide...
Page 130: ...116 IntelliStation A Pro Type 6224 User s Guide...
Page 131: ......
Page 132: ...Part Number 24R8390 Printed in USA 1P P N 24R8390...