– Port with a gear symbol (see Figure 34 on page 64) – Service/Technician port. The SSR will connect a
laptop to this port when performing the ESS 3000 tasks. You need to move the cable when working
on a different canister (two per ESS 3000 unit)
- Logical port enp1s0
Use the following table to fill in the desired IP address for each required interface:
Table 19. ESS 3000 Network preference table
Description
Default
Desired (Fill in)
Target: ESS 3000 unit #1
Canister 1 (top)
Task:
Set the Management interface IP
and subnet mask
Goal:
Specify the desired management
interface IP address for the top
canister of the first ESS 3000 unit
(There may be more than one
unit to deploy). This IP should be
on the same subnet and
reachable as the other IPs
provided in this worksheet.
None.
There is no default IP set from
manufacturing for this port.
Logical interface: enp29s0f0
Physical interface: Port 1
Enter the IP address and subnet
mask.
Ensure that each IP in this
worksheet is on the same subnet.
Recommended subnet is /24
(255.255.255.0)
Keep the canister address below.
128
Recommendation / Example:
Subnet 192.168.45.0
192.168.45.31 netmask
255.255.255.0 (/24)
Target: ESS 3000 unit #1
Canister 2 (bottom)
Task:
Set the Management interface IP
and subnet mask
Goal:
Specify the desired management
interface IP address for the
bottom canister of the first ESS
3000 unit (There may be more
than one unit to deploy). This IP
should be on the same subnet
and reachable as the other IPs
provided in this worksheet.
None.
There is no default IP set from
manufacturing for this port
Logical interface: enp29s0f0
Physical interface: Port 1
Enter the IP address and subnet
mask.
Ensure that each IP in this
worksheet is on the same subnet.
Recommended subnet is /24
(255.255.255.0)
Keep the canister address below.
128
Recommendation / Example:
Subnet 192.168.45.0
192.168.45.30 netmask
255.255.255.0 (/24)
66 IBM Elastic Storage System 3000: Hardware Planning and Installation Guide
Summary of Contents for ESS 3000
Page 5: ...Glossary 83 Index 91 Index 91 v...
Page 6: ...vi...
Page 10: ...x...
Page 70: ...58 IBM Elastic Storage System 3000 Hardware Planning and Installation Guide...
Page 74: ...62 IBM Elastic Storage System 3000 Hardware Planning and Installation Guide...
Page 82: ...70 IBM Elastic Storage System 3000 Hardware Planning and Installation Guide...
Page 90: ...78 IBM Elastic Storage System 3000 Hardware Planning and Installation Guide...
Page 92: ...80 IBM Elastic Storage System 3000 Hardware Planning and Installation Guide...
Page 102: ...90 IBM Elastic Storage System 3000 Hardware Planning and Installation Guide...
Page 107: ......
Page 108: ...IBM Product Number 5765 DME 5765 DAE SC28 3107 01...