Chapter 6. Solving problems
125
pnt0-17
Device fault...Reset initiated!
Explanation:
The SunSoft Solaris device driver has been reset because of a device fault.
Action:
Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation:
This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.
Action:
Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings. Run the NETCONFIG program to search for another
Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings.
pnt0-24
add_intr_handler failed! Vector already shared at different IPL.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-26
The DMA number is not necessary for PCI device.
Explanation:
The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting.
Action:
Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
The IRQ number is already in use.
Explanation:
The specified I/O address is already in use.
Action:
Run the NETCONFIG program to modify your hardware settings.
Table 23. UNIX LLI driver messages for the Ethernet controller.
Summary of Contents for eserver xSeries 350
Page 1: ...User s Reference xSeries 350 ...
Page 2: ......
Page 3: ...IBM IBM xSeries 350 User s Reference SC21 P902 60 ...
Page 12: ...x IBM xSeries 350 User s Reference ...
Page 22: ...10 IBM xSeries 350 User s Reference ...
Page 34: ...22 IBM xSeries 350 User s Reference ...
Page 40: ...28 IBM xSeries 350 User s Reference ...
Page 90: ...78 IBM xSeries 350 User s Reference ...
Page 148: ...136 IBM xSeries 350 User s Reference ...
Page 154: ...142 IBM xSeries 350 User s Reference ...
Page 170: ...158 IBM xSeries 350 User s Reference ...
Page 173: ......
Page 174: ...IBM Part Number 21P9026 21P9 26 ...