116
IBM® xSeries 350: User’s Reference
Printer
Verify that:
1.
The printer is turned on and is online.
2.
The printer signal cable is connected to the correct serial or parallel port on the
server.
Note:
Non-IBM printer cables might cause unpredictable problems.
3.
You have assigned the printer port correctly in your operating system or
application program.
4.
You have assigned the printer port correctly using the Configuration/Setup
Utility program.
If the printer still does not work, run the tests described in the documentation that
comes with your printer. If the tests show that the printer is working correctly, call
for service.
The printer does not work.
Serial port
Verify that:
1.
Each port is assigned a unique address by the Configuration/Setup Utility
program and none of the serial ports is disabled.
Note:
The management port C is the same as a serial port connector, but it is
used only by the integrated Advanced System Management processor
and is not available for use by the operating system. This port does not
appear in the Configuration/Setup Utility program menus; it can be
configured using the systems-management software.
2.
The serial-port adapter, if you installed one, is seated properly.
If the problem persists, call for service.
The number of serial ports
identified by the operating
system is less than the number
of serial ports installed.
A serial device does not work.
Verify that:
1.
The device is compatible with the server.
2.
The serial port is enabled and is assigned a unique address.
3.
Make sure that the device is not connected to the management port C.
Note:
The management port C is the same as a serial port connector, but it is
used only by the integrated Advanced System Management processor
and is not available for use by the operating system. This port does not
appear in the Configuration/Setup Utility program menus; it can be
configured using the systems-management software.
If the problem persists, call for service.
Service processor problems
Disconnect the server from all electrical sources, wait for 30 seconds, reconnect the
server to the electrical sources, and restart the server.
If a problem persists, call for service.
Service Processor Manager
reports a general monitor
failure
Table 18. Troubleshooting charts.
Device and problem
Suggested action
Summary of Contents for eserver xSeries 350
Page 1: ...User s Reference xSeries 350 ...
Page 2: ......
Page 3: ...IBM IBM xSeries 350 User s Reference SC21 P902 60 ...
Page 12: ...x IBM xSeries 350 User s Reference ...
Page 22: ...10 IBM xSeries 350 User s Reference ...
Page 34: ...22 IBM xSeries 350 User s Reference ...
Page 40: ...28 IBM xSeries 350 User s Reference ...
Page 90: ...78 IBM xSeries 350 User s Reference ...
Page 148: ...136 IBM xSeries 350 User s Reference ...
Page 154: ...142 IBM xSeries 350 User s Reference ...
Page 170: ...158 IBM xSeries 350 User s Reference ...
Page 173: ......
Page 174: ...IBM Part Number 21P9026 21P9 26 ...