Страница 4: ...ors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time This publication was developed for products and services offered in the United States of America IBM may not offer the products services or features ...

Страница 5: ...Important This manual is intended for trained servicers who are familiar with IBM PC Server products Before servicing an IBM product be sure to review Safety information on page 149 Important safety information Be sure to read all caution and danger statements in this book before performing any of the instructions Leia todas as instruções de cuidado e perigo antes de executar qualquer operação Pre...

Страница 6: ... Sie eine Anweisung ausführen Accertarsi di leggere tutti gli avvisi di attenzione e di pericolo prima di effettuare qualsiasi operazione Lea atentamente todas las declaraciones de precaución y peligro ante de llevar a cabo cualquier operación Online support Use the World Wide Web WWW to download Diagnostic BIOS Flash Device Driver files and documents The Web address is http www ibm com pc support...

Страница 7: ...ent Firmware 38 Exit 38 Configuring the ASM processor 38 Installing options 41 Notices and statements used in this book 42 Major components of the xSeries 330 43 Major components of the R Pro computer 43 System board 44 System board options connectors 44 System board LEDs 46 Before you begin 46 System reliability considerations 47 Working inside a server workstation with power on 47 Rack installat...

Страница 8: ... disk drive backplane 117 Power supply 117 PCI riser card 118 System board 118 Important Instructions for the IntelliStation R Pro Type 6851 119 Initializing the system board 119 Symptom to FRU index 121 Beep symptoms 121 No Beep symptoms 123 Information panel system error LED 123 Diagnostic error codes 125 Error symptoms 128 POST error codes 129 SCSI error codes 134 Temperature error messages 134...

Страница 9: ... be part of a cluster if The customer identifies the system as part of a cluster One or more external storage units are attached to the system and at least one of the attached storage units is additionally attached to another system or unidentifiable source One or more systems are located near the failing system If the failing system is suspected to be part of a shared DASD cluster all diagnostic ...

Страница 10: ...rror Log If an error was recorded by the system see Chapter Symptom to FRU index on page 121 Start the Diagnostic Programs See Diagnostic programs and error messages on page 15 Check for the following responses a One beep b Readable instructions or the Main Menu 3 DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES NO Find the failure symptom inChapter Symptom to FRU index on page 121 YES Run the Diagno...

Страница 11: ...t flexibility and reliable data storage The xSeries 330 IntelliStation R Pro server workstation comes with a three year limited warranty and IBM server workstation Start Up Support If you have access to the World Wide Web you can obtain up to date information about your xSeries 330 or IntelliStation R Pro model and other IBM server workstation products at the following World Wide Web addresses htt...

Страница 12: ...ocessor One Ultra160 SCSI controller Two 10BASE T 100BASE TX Intel Ethernet controllers Two Universal Serial Bus USB ports Two RS 485 Advanced System Management processor ports one In one Out One serial port Two Cable Chaining Technology ports IN OUT Acoustical noise emissions Sound power idling 6 1 bel maximum Sound power operating 6 2 bel maximum Electrical input Sine wave input 50 60 Hz require...

Страница 13: ... service processor Refer to the documentation provided with the system management software for more information Integrated network environment support The server comes with two Ethernet controllers on the system board Each Ethernet controller has an interface for connecting to 10 Mbps or 100 Mbps networks The server automatically selects between 10BASE T and 100BASE TX Each controller provides ful...

Страница 14: ...urn the server on or off Power on light This green LED lights and stays on when you turn on your server and blinks when the server is in standby mode Reset button Press this button to reset the server and run the power on self test POST You might need to use a pen or the end of a straightened paper clip to press the button Select button indicator Press this button to select the server in the C2T c...

Страница 15: ...thernet port 1 Advanced system management The RS 485 ports in and out are used for creating a system management bus between several servers Select light This green LED lights when the monitor keyboard and mouse are logically connected to this server This light duplicates the Select button LED on the front of the server Cable Chaining Technology OUT This port is used to connect the server to a keyb...

Страница 16: ...te the following steps to turn on the server 1 Plug the power cord of your server into the power source Note Plugging the power cord into a power source may cause the server to start automatically This is an acceptable action 2 Wait 30 seconds then press the power control button on the front of the server You can press the Power control button on the front of the server to start the server Note Af...

Страница 17: ...er in the stand by mode 3 Disconnect the server from the power source Note After turning off the server wait at least 5 seconds before you turn on the server again Stand by mode Stand by puts the server in a wait state When in a wait state the server is not running the operating system and all core logic is shut down except for the service processor Complete the following steps to put the server i...

Страница 18: ...10 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 19: ...f test POST generates beep codes and messages to indicate successful test completion or the detection of a problem See POST on page 12 for more information Diagnostic programs and error messages The server workstation diagnostic programs are stored in upgradable read only memory ROM on the system board These programs are the primary method of testing the major components of your server workstation...

Страница 20: ...the first error message After you correct the cause of the first error message the other error messages usually will not occur the next time you run the test POST error messages The table POST error codes on page 129 provides information about the POST error messages that can appear during startup Event error logs The POST error log contains the three most recent error codes and messages that the ...

Страница 21: ...LEDs that are illuminated can be re illuminated without AC power after you remove the cover This feature helps you isolate the problem if an error causes the server workstation to shut down See Table 3 on page 14 Table 2 SCSI messages SCSI Messages Description All One or more of the following might be causing the problem A failing SCSI device adapter drive controller An improper SCSI configuration...

Страница 22: ...9 Note Refer to Working inside a server workstation with power on on page 47 for instructions and precautions for working in the server workstation with the power on 5 Press and hold the Light Path Diagnostics blue button on the diagnostics panel The LEDs will illuminate while the switch is pressed Note You can illuminate the LEDs for a maximum of two minutes After that time the circuit that power...

Страница 23: ...e function code 089 is for the microprocessor ttt is the three digit failure code that indicates the exact test failure that was encountered iii is the three digit device ID date is the date that the diagnostic test was run and the error recorded cc is the check digit that is used to verify the validity of the information text message is the diagnostic message that indicates the reason for the pro...

Страница 24: ... the test you want to run from the list that appears then follow the instructions on the screen Notes a If the server workstation stops during testing and you cannot continue restart the server workstation and try running the diagnostic programs again b The keyboard and mouse pointing device tests assume that a keyboard and mouse are attached to the server workstation c If you run the diagnostic p...

Страница 25: ...start the server workstation 2 When the message F2 for Diagnostics appears press F2 If a power on password is set the server workstation prompts you for it Type in the appropriate password then press Enter 3 When the Diagnostic Programs screen appears select Utility from the top of the screen 4 Select View Test Log from the list that appears then follow the instructions on the screen The system ma...

Страница 26: ...upport and make the selections for your server workstation Contact your IBM service representative To recover the BIOS 1 Turn off the server workstation and peripheral devices and disconnect all external cables and power cords then remove the cover 2 Locate the BIOS code page jumper J19 on the system board 3 Place a jumper on pins 1 and 2 to enable BIOS back page 4 Reconnect all external cables an...

Страница 27: ...ists try a different cable If you set the Ethernet controller to operate at 100 Mbps you must use Category 5 cabling If you directly connect two workstations without a hub or if you are not using a hub with X ports use a crossover cable Note To determine whether a hub has an X port check the port label If the label contains an X the hub has an X port Determine if the hub supports auto negotiation ...

Страница 28: ...share interrupts with LAN controllers Make sure that you are using the most recent device driver available from the World Wide Web Run the network diagnostic program Data is incorrect or sporadic Check the following Make sure that you are using Category 5 cabling when operating the server workstation at 100 Mbps Make sure that the cables do not run close to noise inducing sources like fluorescent ...

Страница 29: ...the Windows NT desktop select Start Control Panel Networks Adapters 2 Select your IBM Ethernet adapter from the list 3 Select Properties Advanced 4 Lower the resource values that apply to the receive queue 0x0F Explanation Could not allocate enough memory for other structures Action 1 From the Windows NT desktop select Start Control Panel Networks Adapters 2 Select your IBM Ethernet adapter from t...

Страница 30: ...None 10 Warning Explanation Team nn Adapter link down Action Make sure the adapter is functioning properly 11 Informational Explanation Team nn Secondary adapter took over Action None 12 Warning Explanation Team nn Secondary adapter is deactivated from the Team Action Make sure the secondary adapter is functioning properly and that the adapter cable is securely connected to the LAN 13 Informationa...

Страница 31: ...r supply b System board c 1 Microprocessor d 1 Terminator card e Memory module with a minimum of 128 MB DIMM 4 Reconnect the AC cord and power on the system If the system powers up successfully replace adapters and devices one at a time until the problem is isolated If system does not power up from minimal configuration replace FRUs of minimal configuration one at a time until the problem is isola...

Страница 32: ...ect all external cables and power cords 3 Remove the server workstation from the rack see Rack installation on page 47 4 Remove the cover see Removing the cover on page 49 5 Remove the battery a Use one finger to lift the battery clip over the battery b Use one finger to slightly slide the battery out from its socket The spring mechanism will push the battery out toward you as you slide it from th...

Страница 33: ...kstation and 100 mm 4 inches at the rear of the server workstation The top cover is removed for no longer than 30 minutes while the server workstation is operating A removed hot swap drive is replaced within two minutes of removal Cables for optional adapters are routed according to the instructions provided with the adapters ensure that cables are not restricting air flow The fans are operating c...

Страница 34: ...26 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 35: ...an use this program to change network boot protocols and boot order to select OS wake up support and to set menu wait times ServeRAID programs If there is a ServeRAID adapter installed in the server workstation you must use the ServeRAID configuration program to define and configure your disk array subsystem before you install your operating system Advanced System Management Utility An additional ...

Страница 36: ... fields This choice appears on both the full and limited Configuration Setup Utility menus System Information Select this choice to display information about the server workstation Changes that you make on other menus might appear on this summary screen You cannot edit any fields The System Information choice appears only on the full Configuration Setup Utility main menu Product Data Select this c...

Страница 37: ...t Processor each time the server workstation is started Use the number keys to enter the hours and minutes and or to add or subtract from the system time If you want the system clock time to be the same as the Advanced System Management Processor clock time leave the value set at its default of 0 System Security Select this choice to set passwords or a system owner s name This choice appears only ...

Страница 38: ...em Partition is visible To make the System Partition visible set this value to Visible To make the System Partition invisible set this value to Hidden Core Chipset Control Select this choice to modify settings that control features of the core chip set on the system board Attention Do not make changes here unless directed to do so by an IBM authorized service representative Cache Control Select th...

Страница 39: ...te your changes and restore the previous settings Load Default Settings Select this choice to cancel your changes and restore the factory settings Exit Setup If you have made any changes the program will prompt you to save the changes or exit without saving the changes Using passwords The System Security choice appears only on the full Configuration Setup Utility menu After you select this choice ...

Страница 40: ...ing to use the power on password But if you do not use the Configuration Setup Utility program to change or delete the password the next time you start the server workstation the original power on password will be reinstated 4 Connect the server workstation to a power source keyboard monitor and mouse 5 Power up the server workstation Note You can now start the Configuration Setup Utility program ...

Страница 41: ...to select a choice from the menu Press Esc to return to the previous menu Press the F5 key to switch between color and monochrome modes if your monitor permits Table 7 Power on and administrator password features Typeofpassword Results Power on password Enter the password to complete the system startup A limited set of choices is available on the Configuration Setup Utility main menu Administrator...

Страница 42: ...SCSI Device Configuration Select this choice to configure SCSI device parameters Before you can make updates you must know the ID of the device whose parameters you want to configure Note The Maximum Sync Transfer Rate represents the transfer rate for Ultra SCSI devices The transfer rate for Ultra3 SCSI LVD devices is 160 0 The transfer rate for Ultra2 SCSI LVD devices is 80 0 The transfer rate fo...

Страница 43: ... F4 key to exit 4 Follow the instructions on the screen to change the settings of the selected items then press Enter PXE Boot Agent Utility menu choices The following choices appear on the PXE Boot Agent Utility menu Network Boot Protocol PXE is the default value for this menu item Note Do not change this value There are no other network boot protocols supported Boot Order Select this choice to c...

Страница 44: ...telliStation R Pro Advanced System Management Firmware Update Utility program to create an xSeries 330 IntelliStation R Pro Advanced System Management Firmware Update Utility diskette Use the xSeries 330 IntelliStation R Pro Advanced System Management Firmware Update Utility diskette to update the ASM firmware or configure ASM processor settings With the configuration utility you can Configure Ale...

Страница 45: ...r When you finish viewing this information press Esc to return to the main menu Configuration Settings Select Configuration Settings to view or change the configuration settings of the ASM processor Select this choice to configure the following settings Alert Settings Dial In Out Settings General Settings Modem Settings Alert Settings Select this choice to enable or disable all critical non critic...

Страница 46: ... time and date of the ASM clock schedule a time and date for the system to be automatically powered on and to specify POST Loader and O S Timeout values or the Power Off Delay value The Name and Number help you identify these systems on your network The Name and Number values can be up to 15 characters in length Use the arrow keys and the Tab key to move between the fields When you finish press F6...

Страница 47: ...haracters long Notes a The Name and Number designations apply to the ASM processor and not to the server b Designate the ASM processor with names and numbers that correspond to the server designations to which they apply 6 Press F6 to save the values and return to the main menu To return to the main menu without saving press Esc 7 When you are finished using the utility program select Exit Utility...

Страница 48: ...40 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 49: ...uctions to help you add options to the server workstation Some option removal instructions are provided in case you need to remove one option to install another For a list of supported options for the server workstation see the Server Proven list at http www ibm com pc compat ...

Страница 50: ...rovide information or advice that might help you avoid inconvenient or problem situations Attention These notices indicate possible damage to programs devices or data An attention notice is placed just before the instruction or situation in which damage could occur Caution These notices indicate situations that can be potentially hazardous to you A caution statement is placed just before the descr...

Страница 51: ...components in the server workstation Major components of the R Pro computer The following illustration shows the locations of major components in your computer Microprocessor Terminator card Fans Hard disk drive filler panel Hard disk drive Memory module Air baffle Light Path Diagnostics Clear shield Heatsink Clip ...

Страница 52: ... following sections show the components on the system board System board options connectors The following illustration identifies the connectors on the system board Microprocessor Terminator card Fans Filler panel Hard disk drive Memory module Air baffle Light Path Diagnostics Clear shield Heatsink Clip Audio card Video card ...

Страница 53: ...on for each switch Table 8 Switches 1 4 Switch number Switch description 1 Force power on The default setting is Off disabled 2 Reserved The default setting is Off 3 Reserved The default setting is Off Serial port A J52 Serial port B J51 Management port J53 C2T in port U38 C2T out port U61 USB 2 port J15 USB 1 port J13 RS 485 Advanced System Management interconnect ports J5 Ethernet ports J1 PCI s...

Страница 54: ...s for the server workstation monitor and any other options that you intend to install Back up all important data before you make changes to disk drives Have a small flat blade screwdriver available 4 Bypass power on password When toggled to the opposite position bypasses the power on password if one is set for one boot cycle See Setting the password override switch on page 32 Table 8 Switches 1 4 ...

Страница 55: ... according to the instructions provided with the adapters A failed fan is replaced within 48 hours Working inside a server workstation with power on Your server workstation is designed to operate safely while turned on with the cover removed Follow these guidelines when you work inside a server workstation that is turned on Avoid loose fitting clothing on your forearms Button long sleeved shirts b...

Страница 56: ... Using the thumb screws on the front of the server workstation secure the server workstation to the brackets 4 If you have additional servers workstations to install repeat steps 1 through 3 for each server workstation 5 Install all external cables and power cords to the server workstations ...

Страница 57: ...ime over 30 minutes with the cover removed might damage server workstation components 7 Remove the clear shield that covers the inside of the server workstation Note It is not necessary to remove the shield when you are installing memory modules or installing an adapter in the PCI slots Working with adapters in the xSeries 330 The server workstation comes with two peripheral component interconnect...

Страница 58: ...apters it does not support 3 3 V only adapters Your server workstation uses a rotational interrupt technique to configure PCI adapters Because of this technique you can install PCI adapters that currently do not support sharing of PCI interrupts PCI slots 1 and 2 and the integrated SCSI controller are on PCI bus B the system board and all other integrated devices are on PCI bus A Note PCI bus A bu...

Страница 59: ...f the server workstation and peripheral devices and disconnect all external cables and power cords 3 Remove the server workstation from the rack then remove the cover as shown For more information see Removing the cover on page 49 4 Remove the expansion slot clip that holds the expansion slot cover in place by sliding it upward and off the frame of the server workstation Note The illustrations in ...

Страница 60: ...d c Press the adapter firmly into the riser card connector Attention When you install an adapter be sure the adapter is correctly seated in the riser card connector before you turn on the server workstation Improperly seated adapters might cause damage to the system board the riser card or the adapter d Push down on the blue adapter retention latch until it clicks into place securing the adapter e...

Страница 61: ...document might differ slightly from your hardware Adapter considerations If you ever need to install an adapter be sure to review the following Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this chapter If you need to change the switch settings or jumper settings on your adapter follow the instructions that come with the adapt...

Страница 62: ... 49 for instructions 4 Remove the expansion slot clip that holds the expansion slot cover in place by sliding it upward and off the frame of the computer 5 Remove the adapter according to the notes below Notes a For the audio adapter 1 Disconnect the audio cable that connects to the video adapter 2 Slide the adapter horizontally to disconnect it from the riser card b For the video adapter you must...

Страница 63: ...ions Attention You should route adapter cables before you install the adapter 7 Set any jumpers or switches as described by the adapter manufacturer 8 Install the adapter Note When installing an adapter in PCI slot 2 skip steps a and d a Open the adapter retention latch by pushing the blue tab to release it Then push the latch up to the full open position b Carefully grasp the adapter by its top e...

Страница 64: ...nstalling the Remote Supervisor Adapter perform the following tasks Obtain the most recent device drivers Advanced System Management ASM firmware DOS configuration utility and management information base MIB from the IBM Support Web site http www ibm com pc support See Advanced System Management on page 36 Install the operating system on your server before you install the Advanced System Managemen...

Страница 65: ...ing systems Novell NetWare 4 2 or later Microsoft Windows NT 4 0 Server with Service Pack 4 or later Microsoft Windows 2000 Server Microsoft Windows 2000 Advanced Server SCO UnixWare 7 1 1 or later Documentation that comes with your server If you want to access the Remote Supervisor Adapter remotely through a Web browser the supported Web browsers and browser requirements are Microsoft Internet Ex...

Страница 66: ...ervisor Adapter in Adobe Acrobat Portable Document Format PDF The publications on the CD are IBM Remote Supervisor Adapter Installation Guide this book IBM Remote Supervisor Adapter User s Guide for the xSeries 330 The User s Guide describes the features and functions of the Advanced System Management ASM Web interface and the text based user interface IBM Safety Book Before you install the Remote...

Страница 67: ...cumentation CD select from a list of available topics see brief descriptions of the selected topics and view selected topics using Adobe Acrobat Reader Note The first time you run the Documentation Browser you need to configure the preferences for your system The Preferences window opens automatically Use the Preferences window to specify the location of your Adobe Acrobat Reader if installed or t...

Страница 68: ...visor Adapter and describe the Remote Supervisor Adapter components You can install the Remote Supervisor Adapter in a peripheral component interconnect PCI slot only Inventory checklist The Remote Supervisor Adapter option contains the following items Remote Supervisor Adapter Power supply adapter Power cord 20 pin ribbon cable Advanced System Management link cable CAT 5 Ethernet cable P P ...

Страница 69: ...he Ethernet connector on the Remote Supervisor Adapter do not plug the ASM Interconnect module into the Ethernet RJ 45 port IBM Remote Supervisor Adapter Support CD This CD helps you configure hardware and install device drivers IBM Documentation CD The contents of this CD are described in About your documentation on page 58 ...

Страница 70: ... the other devices on the ASM Interconnect network Power and error LEDs The green power LED indicates the status of the power connection The amber Error LED indicates an error on the Remote Supervisor Adapter External power supply connector Connect the power supply adapter comes with the Remote Supervisor Adapter to this connector This connection provides power to the Remote Supervisor Adapter ind...

Страница 71: ... and disconnect all external cables and power cords 3 To remove the cover complete the following steps a Remove the server from the rack if necessary b Remove the two screws from the back of the server c Pull out on the cover release lever at the back of the server to release the cover d Slide the cover back then up and off the server Attention For proper cooling and airflow replace the cover befo...

Страница 72: ... connector before you apply power Incomplete insertion might cause damage to the system board or the adapter Note that power can also be provided to the adapter through the system management connector for the location of this connector see Remote Supervisor Adapter components on page 62 7 Connect the internal cables to the adapter Note that the 20 pin ribbon cable see Inventory checklist on page 6...

Страница 73: ...mote Supervisor Adapter to connect the power supply adapter to a power distribution unit PDU or to an uninterruptible power supply UPS Note Alternatively power can be supplied to the adapter by connecting the system management connector of the adapter to the Remote Supervisor Adapter connector J57 on the system board using the 20 pin ribbon cable that comes with the adapter To connect the power su...

Страница 74: ...es Connecting the LAN and serial port cables You can manage your server remotely using the connections and user interfaces that are described in Table 9 Choose the interface method you want to use to perform remote management then perform the indicated cabling procedure If you plan to set up an ASM interconnect network go to Planning and cabling your interconnect network on page 77 for instruction...

Страница 75: ...ustration Ethernet link The green Ethernet link LED is lit when the Ethernet cable is connected properly Text based user interface using a modem or a null modem Serial COM port Cabling the serial COM port on page 68 ASM Web interface using point to point PPP protocol Text based user interface using the TELNET protocol over PPP Table 9 Cabling tasks to enable remote access to the Remote Supervisor ...

Страница 76: ...ware code from the IBM Support Web site http www ibm com pc support After you initially configure the Remote Supervisor Adapter to enable remote access through a Web connection you can update the Remote Supervisor Adapter firmware using the ASM Web interface The procedures to initially configure the Remote Supervisor Adapter for remote access are described later in this chapter For information abo...

Страница 77: ...wn Arrow keys and to select Update System Management Firmware then press Enter A warning window opens 5 Press Enter to continue The Firmware Update Options Menu window opens 6 Use the arrow keys to select Normal Flash All subsystems then press Enter ...

Страница 78: ...ge to confirm you want to update the firmware Press Enter The system updates the Remote Supervisor Adapter firmware 8 When the Remote Supervisor Adapter firmware update process is complete press Enter to return to the Utility program main window Continue with Configuring your system to enable remote access to the Remote Supervisor Adapter on page 71 ...

Страница 79: ... have a DHCP server on your network complete the following steps to configure the Ethernet port 1 If you completed the update firmware procedure and the Utility program main window is open go to step 4 otherwise continue with step 2 2 Turn on the server 3 Insert the IBM Remote Supervisor Adapter Support CD into the CD ROM drive and close the CD ROM drive before the server completes POST The CD sta...

Страница 80: ...net Settings window opens Note The values in the following window are only examples your settings will be different 6 Use the arrow keys to navigate to each field Your system administrator can provide the information for the following fields Network Interface The default value is Enabled verify that it is still set to Enabled IP Address Type the IP address of the Remote Supervisor Adapter Subnet M...

Страница 81: ...ervisor Adapter restarts automatically Continue with Completing the installation on page 76 Configuring the serial port To configure the Remote Supervisor Adapter serial port for access using a modem or null modem complete the following steps 1 If you completed the procedure for configuring the Ethernet port and the Configuration Settings window is open go to step 5 otherwise continue with step 2 ...

Страница 82: ... port settings press F6 to apply the changes 8 Press Esc to return to the Configuration Settings window 9 If you need to set up PPP go to Setting up point to point protocol otherwise continue with step 10 10 Press Esc to return to the Utility program main window 11 Use the arrow keys to select Exit Utility from the menu or press Esc to close the Utility program 12 Remove the CD from the CD ROM dri...

Страница 83: ... window opens 5 Use the Up Arrow and Down Arrow keys and to select Configuration Settings then press Enter The Configuration Settings window opens 6 Use the arrow keys to select PPP Settings then press Enter The PPP Settings window opens Note The values in the following windows are only examples your settings will be different 7 Use the arrow keys to navigate to each field Verify the values in the...

Страница 84: ...e alert notification Monitoring remote server status using the ASM Web interface or a text based user interface If you want to set up an ASM interconnect network continue to Planning and cabling your interconnect network on page 77 Your ASM interconnect network can include as many as 12 individual ASM connections in a single bus These connections can include Remote Supervisor Adapters ASM processo...

Страница 85: ...with terminated beginning and end points Make sure that the total combined length of all Ethernet cables connecting the server in the ASM interconnect network does not exceed 91 4 M 300 ft Each Remote Supervisor Adapter ASM PCI adapter or ASM processor that is connected to the ASM interconnect network bus counts as one connection For example if an ASM PCI adapter is installed in a server that has ...

Страница 86: ...tached When alerts are generated they are forwarded to the Remote Supervisor Adapter ASM processor or ASM PCI adapter on the ASM interconnect network that has the communication resources to forward the alert If no system on the ASM interconnect network meets the requirements the alert is set for transmission if the connection type is configured or becomes available later If multiple modems or mult...

Страница 87: ...complete the following steps 1 Connect the ASM Interconnect module to the ASM Interconnect port Note The following illustration shows a Remote Supervisor Adapter installed in an xSeries 330 server 2 Connect one end of the ASM link cable Cat 5 or 3 Ethernet cable to the ASM Interconnect module and connect the other end of the link cable to the RS 485 port Netfinity 4500R or xSeries 340 yes xSeries ...

Страница 88: ...t network forwarding system management data generated by the other systems in the ASM interconnect network bus to the system management administration system that is connected to the network This is an environment that is using all xSeries 330 servers Note You might need to supply additional cables or connectors to set up the ASM interconnect network Redundant Power RS 485 Server 2 Server 1 Server...

Страница 89: ...rvisor Adapter will act as the network interconnect forwarding system management data generated by the other systems in the ASM interconnect network bus to the system management administration system that is connected to the network This is an environment that is using all xSeries 330 servers RS 485 A RS 485 A RS 485 A RS 485 B RS 485 B RS 485 B Ethernet cable with RJ 45 connectors Redundant Power...

Страница 90: ...cing modems at opposite ends of the ASM interconnect network bus ensures that if an ASM interconnect connection in the bus fails all of the systems on the ASM interconnect network have access to a modem to forward system management data to the remote system management administrator This is an environment with different models of servers Hard disk drives The server workstation supports two 1 inch 2...

Страница 91: ... the SCSI IDs for the hard disk drives Preinstallation steps Before you install a hard disk drive review the following Inspect the drive tray for any signs of damage Ensure that the drive is installed properly in the tray To maintain proper system cooling do not operate the server workstation for more than two minutes without either a drive or a filler panel installed in each bay If your server wo...

Страница 92: ...es and power cords then turn on the server workstation 6 Check the hard disk drive status indicators to verify that the hard disk drives are operating properly See Server controls and indicators on page 6 for the location of the status indicators When the green light flashes rapidly three flashes per second the controller is identifying the drive Replacing a hard disk drive is done in the same man...

Страница 93: ...emove the PCI card in slot 2 for easier access to the DIMM connectors 4 Touch the static protective package containing the DIMM to any unpainted metal surface on the server workstation Then remove the DIMM from the package Attention To avoid breaking the retaining clips or damaging the DIMM connectors handle the clips gently 5 Install the DIMM in the connector Attention To prevent damage to the DI...

Страница 94: ... of connectors that you want to enabled and then select Enable In some memory configurations the 3 3 3 beep code might sound during POST followed by a blank display screen If this occurs and the Boot Fail Count feature in the Start Options of the Configuration Setup Utility is set to Enabled its default setting you must restart the server workstation three times a three boot reset to force the sys...

Страница 95: ...arted Attention To avoid damage and ensure proper server workstation operation install microprocessors that are the same type and have the same cache size and the same clock speed Microprocessor internal clock frequencies and external clock frequencies must be identical See the serverProven list at http www ibm com pc compat for a list of microprocessors for use with the server workstation Install...

Страница 96: ...erver workstation then remove the microprocessor from the package b Orient the microprocessor over the microprocessor connector as shown in the illustration Carefully press the microprocessor into the connector Note To avoid bending the pins on the microprocessor do not use excessive force when pressing it into the connector 6 Push the microprocessor release lever down to lock the microprocessor i...

Страница 97: ...al cables then remove the cover see Removing the cover on page 49 for details 3 Remove the clear shield from the server workstation and store it in a safe place 4 To remove microprocessor 2 a Remove the clip from the heat sink by pushing forward on the back of the clip and up on the lever After the clip releases from the heat sink lift it up and off the heat sink Note A thermal material is used be...

Страница 98: ...ce 3 Lift the retainer latch up and off the system board b Follow steps a on page 89 through d on page 89 c After the replacement microprocessor reinstall the adapter board retainer latch by reversing step a above Note If a terminator card is being installed in microprocessor slot 1 it is not necessary to replace the adapter retainer latch Clip Heat sink Microprocessor Terminator card Heat sink re...

Страница 99: ...48 hours to help ensure proper cooling The following illustration shows the replacement of a fan Note The illustrations in this document might differ slightly from your hardware Complete the following steps to replace the fan assembly Clip Heatsink Microprocessor Terminator card Heatsink release lever Slot Top view of heatsink Retainer clip Air flow ...

Страница 100: ... workstation 5 Remove the fan from the server workstation a Disconnect the fan cable from the system board b Lift the fan away from the server workstation 6 Install the replacement fan a Orientate the fan so that the air flow arrow on the side of the fan is facing or pointing toward the rear of the server workstation Note Proper air flow is from the front to the rear of the server workstation b Pu...

Страница 101: ...ition and sliding it forward Make sure the cover engages the tabs at the front and rear of the server workstation Attention Before sliding the cover forward make sure that all of the tabs on the cover will engage the ledge at the front of the server workstation properly If all of the tabs do not engage the ledge properly it will be extremely difficult to remove the cover 4 Install the screws and s...

Страница 102: ...ors see Input Output ports Input Output ports This section provides information about the input output I O ports on your computer These ports include the following Console ports Serial port Universal Serial Bus USB ports Ethernet ports Advanced System Management ASM ports Audio ports Video ports Ethernet 1 Ethernet 2 PCI slot 1 video adapter PCI slot 2 audio adapter RS 485 Advanced System Manageme...

Страница 103: ...s are P N 15912 01 and P N 15941 00 Keyboard connector There is one keyboard connector on the end of the device breakout cable This connector is identified by the keyboard icon Note If you attach a standard non USB keyboard to the keyboard connector the USB ports and devices will be disabled during the power on self test POST The following table shows the pin number assignments for the keyboard co...

Страница 104: ... address assignments to prevent or resolve address conflicts This serial port is also manually configurable from inside of the computer The following table lists the function of each of the connectors that you can use to manually configure the serial port You will also need to refer to the figure in System board options connectors on page 44 Viewing or changing the serial port assignments To view ...

Страница 105: ...press Enter Note The Devices and I O Ports choice appears only on the full configuration menu If you set two levels of passwords you must enter the administrator password to access the full configuration menu 4 Select the serial port then use the arrow keys to advance through the settings available 5 Select Save Settings then select Exit Setup to exit from the Configuration Setup Utility main menu...

Страница 106: ...be disabled during the power on self test POST 2 If you install a USB keyboard that has a mouse port the USB keyboard emulates a mouse and you will not be able to disable the mouse settings in the Configuration Setup Utility program USB cables and hubs You need a 4 pin cable to connect devices to USB 1 or USB 2 If you plan to attach more than two USB devices you must use a hub to connect the devic...

Страница 107: ...rk data rate whether the data rate is standard Ethernet 10BASE T Fast Ethernet 100BASE TX half duplex HDX or full duplex FDX The controllers support half duplex HDX and full duplex FDX modes at both speeds The Ethernet controllers are PCI Plug and Play devices You do not need to set any jumpers or configure the controllers for your operating system before you use the Ethernet controllers However y...

Страница 108: ...tp www ibm com networking support Priority Packet prioritizes traffic based on priority filters These are parameters you assign to outgoing transmit packets Using the Priority Filter Wizard you can set up predefined or custom priority filters based on a node MAC address Ethernet type or by various properties of the protocol and port Priority Packet provides two different methods for prioritizing t...

Страница 109: ...ysical grouping or collision domains Using VLANs increases network performance and improves network security VLANs offer you the ability to group users and devices together into logical workgroups This can simplify network administration when connecting clients to computers that are geographically dispersed across the building campus or enterprise network Normally VLANs are configured at the switc...

Страница 110: ...AN name is for information only and does not need to match the name on the switch 7 Repeat steps 3 through 5 for each VLAN you want the computer to join Click on the plus sign next to the selected adapter to view the VLANs you added 8 Click OK Ethernet port connector The following table shows the pin number assignments for the RJ 45 connector These assignments apply to both 10BASE T and 100BASE TX...

Страница 111: ...each other in half duplex mode Audio ports The audio adapter is standard in the IntelliStation R Pro workstation The audio adapter ports are standard ports The computer has an integrated audio controller Using the audio controller you can record sound and music You can also play sound with multimedia applications The following illustration shows the location of the audio adapter connectors and por...

Страница 112: ... This serial port is also manually configurable from inside of the server workstation The following table lists the function of each of the connectors which can be used to manually configure the serial port You will also need to refer to the figure in System board options connectors on page 44 Viewing or changing the serial port assignments To view or change the serial port assignments Connectors ...

Страница 113: ...emerging serial interface standard for telephony and multimedia devices It uses Plug and Play technology to determine the type of device attached to the connector Notes 1 If you attach a standard non USB keyboard to the keyboard connector the USB ports and devices will be disabled during the power on self test POST 2 If you install a USB keyboard that has a mouse port the USB keyboard emulates a m...

Страница 114: ...s the Ethernet controller will adjust to the network data rate whether the data rate is standard Ethernet 10BASE T Fast Ethernet 100BASE TX half duplex HDX or full duplex FDX The controller supports half duplex HDX and full duplex FDX modes at both speeds The Ethernet controller is a PCI Plug and Play device You do not need to set any jumpers or configure the controller for your operating system b...

Страница 115: ...ng support Priority Packet prioritizes traffic based on priority filters These are parameters you assign to outgoing transmit packets Using the Priority Filter Wizard you can set up predefined or custom priority filters based on a node MAC address Ethernet type or by various properties of the protocol and port Priority Packet provides two different methods for prioritizing traffic IEEE 802 1p tagg...

Страница 116: ...logical grouping of network devices put together as a LAN regardless of their physical grouping or collision domains Using VLANs increases network performance and improves network security VLANs offer you the ability to group users and devices together into logical workgroups This can simplify network administration when connecting clients to server workstations that are geographically dispersed a...

Страница 117: ...ystem Management ports There are two kinds of Advanced System Management ports a Management port Serial port A and RS 485 ports Management Port Serial port A This port uses a standard D shell serial port connector labeled A on the rear of the server workstation You can attach a dedicated modem to the D shell connector on the rear of the server workstation to communicate with the integrated Advance...

Страница 118: ...cables in the ASM bus Use standard unshielded twisted pair UTP cables with RJ 45 connectors Note For more information about the ASM PCI adapter see the documentation that came with the adapter The servers in the ASM bus are referred to by their assigned addresses and not their positions in the rack Complete the following steps to connect the ASM bus 1 Turn off the servers 2 Locate the RS 485 conne...

Страница 119: ...he C2T chaining cables When connecting servers across a space larger than 3 U or on two separate racks you must use a C2T interconnect cable that is 2 m 6 5 ft long which is available in the C2T option cable kit Note Only one 2 m 6 5 ft cable can be used in the C2T chain The C2T chaining cables are hot swappable Attention Do not let the pins of the C2T cable connectors touch the server chassis whe...

Страница 120: ...Server 1 usually the server at the bottom of the rack is the server to which you connect the device breakout cable 3 Turn on the servers then check the operation of the monitor pointing device and keyboard with each server See Testing the C2T chain for testing instructions Note Write on adhesive labels have been provided so that you can label the positions of the servers in the rack Testing the C2...

Страница 121: ...that server illuminates Server 1 usually the server at the bottom of the rack is the server to which you connect the C2T breakout cable Server 1 must not be turned off powered down for the chain to work properly If server 1 is turned off powered down it must be removed from the chain and replaced by the next server in the chain Servers are numbered by their position in the chain 1 through n If one...

Страница 122: ...114 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 123: ...ette CD ROM drives To remove the diskette CD ROM drive 1 Power off the server workstation 2 Remove the cover See Removing the cover on page 49 3 Disconnect the cables for the floppy disk drive and the CD ROM drive from the system board 4 Remove the fans See Fan assembly replacement on page 91 5 Remove the screws 6 Gently pull the CD ROM diskette drive subassembly up and back simultaneously to remo...

Страница 124: ...d by gently pulling the cable up until it is released from the connector 2 To replace the diskette drive cable pull up on the connector latch until it is unlocked then insert the end of the cable into the connector and gently push down on the connector latch until it clicks into place 3 Remove the CD ROM drive a Remove the CD ROM drive retaining wire by releasing it from the metal tab and removing...

Страница 125: ...the server workstation 2 Remove the cover See Removing the cover on page 49 3 Disconnect the backplane cable from the system board 4 Pull out the hard drives in order to disconnect them from the backplane 5 Remove the screw from the top of the backplane bracket 6 Gently but firmly lift the backplane bracket and board up from the chassis Power supply To remove the power supply Note Read Safety info...

Страница 126: ...rom the side of the chassis and lift up to remove PCI riser card To remove the PCI riser card Note Read Safety information on page 149 and Before you begin on page 46 1 Power off the server workstation 2 Remove the cover See Removing the cover on page 49 3 Remove any adapters and put them in a safe place 4 Disconnect cables 5 Gently lift up on the card to disconnect it from the system board port S...

Страница 127: ...words IntelliStation BIOS http www pc ibm com us files html If Web access is not available to you use the IBM IntelliStation R Pro Type 6851 BIOS Update diskette provided with this FRU Initializing the system board To initialize he new system board do the following 1 After you replace the system board insert the IBM IntelliStation R Pro Type 6851 BIOS Update diskette and turn on the system 2 Resol...

Страница 128: ...nd IntelliStation R Pro Type 6851 10 Press Enter again to continue 11 Set the correct date and time 12 Highlight Exit Setup then press Enter 13 Highlight Yes save and exit the Setup Utility then press Enter Initialization of the new system board is complete ...

Страница 129: ... beep after successfully completing POST indicates the system is functioning properly Beeps Description 1 2 3 One beep A pause or break Two beeps A pause or break Three Beeps 4 Four continuous beeps Beep Symptom FRU Action 1 1 2 Processor register test failed 1 Optional Processor if installed 2 Processor 1 1 3 CMOS write read test failed 1 Battery 2 System Board 1 1 4 BIOS EEPROM checksum failed 1...

Страница 130: ...race failed 1 System Board 2 3 4 Search for video ROM failed 1 System Board 2 4 1 Video failed screen believed operable 1 System Board 3 1 1 Timer tick interrupt failed 1 System Board 3 1 2 Interval timer channel 2 failed 1 System Board 3 1 3 RAM test failed above address OFFFFH 1 DIMM 2 System Board 3 1 4 Time Of Day clock failed 1 Battery 2 System Board 3 2 1 Serial port failed 1 System Board 3 ...

Страница 131: ...ory in system 1 Install or reseat the memory modules then do a 3 boot reset See Using the Configuration Setup Utility program on page 27 2 DIMMs 3 System Board Two Short Beeps Information only the configuration has changed 1 Run Diagnostics 2 Run Configuration Setup Three Short Beeps 1 DIMM 2 System Board One Continuous Beep 1 Processor 2 Optional Processor if installed 3 System Board Repeating Sh...

Страница 132: ...rive bay that the failing drive is installed in will be turned on 1 Failing drive 2 Be sure the fans are operating correctly and the air flow is good 3 SCSI Backplane FAN LED on 1 Check individual fan LEDs 2 Replace respective fan 3 System Board MEM LED on The LED next to the failing DIMM is on 1 DIMM 2 Failing DIMM in slot J1 J4 3 System Board PCI LED on 1 Remove PCI adapters from slots 1 2 2 Sys...

Страница 133: ...em board Should connect to Serial Port A on the system board J52 3 System Board 011 XXX 001 Failed COM2 Serial Port test 1 Check loopback plug connected to externalized serial port 2 Check cable from externalized port to system board Should connect to Serial Port B on the system board J51 3 System Board 014 XXX 000 Failed Parallel Port test 1 System Board 015 XXX 001 USB interface not found board ...

Страница 134: ...and option power cords from server workstation wait 30 seconds reconnect and retry 4 System Board 165 201 000 Service Processor Failed 1 Disconnect all server workstation and option power cords from server workstation wait 30 seconds reconnect and retry 2 System Board Before replacing the System Board ensure that System Board jumper J28 is not installed the default when the error occurs 165 330 00...

Страница 135: ...isk number refers to the RAID logical array 1 Fixed Disk 2 2 System Board 264 XXX 0NN Failed Tape Drive test 1 Tape Cartridge if user executed the Read Write Tape Drive test failure code of XXX 256 2 SCSI or Power Cable connected to tape drive with SCSI ID NN 3 Tape Drive with SCSI ID NN Refer to the Help and Service Information appendix of the tape drive s User Guide 4 System Board or SCSI Contro...

Страница 136: ...k for correct device driver 4 Run CD ROM diagnostics 5 CD ROM Drive 6 System Board Power switch does not work and reset button does work SW 1 1 is force power on switch 1 Reseat connector 2 Switch Card 3 System Board Diskette drive in use light stays on or the system bypasses the diskette drive or the diskette drive does not work 1 If there is a diskette in the drive verify that a The diskette dri...

Страница 137: ...tic If successful replace the drive you removed Not all drives are recognized by fixed disk diagnostic 1 Remove first drive that does not show up and rerun diagnostic If remaining drives show up replace the one that was removed 2 If remaining drives do not show up remove successive drives one at a time and rerun diagnostic System hangs during fixed disk diagnostic 1 Remove hard drive being tested ...

Страница 138: ...tion Setup 2 System Board 177 178 Security hardware error 1 Run Configuration Setup 2 System Board 184 Power on password corrupted 1 Run Configuration Setup 2 System Board 185 Drive startup sequence information corrupted 1 Run Configuration Setup 2 System Board 186 Security hardware control logic failed 1 Run Configuration Setup 2 System Board 187 VPD serial number not set 1 Set serial number in S...

Страница 139: ...un Configuration Setup and Diagnostics 2 Diskette Drive 3 Drive Cable 4 System Board 605 Unlock failure 1 Diskette Drive 2 Drive Cable 3 System Board 662 Diskette drive configuration error 1 Run Configuration Setup and Diagnostics 2 Diskette Drive 3 Drive Cable 4 System Board 762 Coprocessor configuration error 1 Run configuration setup 2 Battery 3 Processor 962 Parallel port error 1 Disconnect ex...

Страница 140: ...ration error IDE drive only 1 Fixed Disk Drive 2 Fixed Disk Cables 3 Run Configuration Setup 4 System Board 178X Fixed Disk error IDE drive only 1 Fixed Disk Cables 2 Run Diagnostics 3 Fixed Disk Drive 4 System Board 1800 No more hardware interrupt available for PCI adapter 1 Run Configuration Setup 2 Remove Adapter 1801 no more ROM space available for PCI adapter 1 Run Configuration Setup 2 Remov...

Страница 141: ...dapter to slot 1 or 2 3 Failing Adapter 4 System Board 00180500 PCI option ROM checksum error 1 Remove Failing PCI Card 2 System Board 00180600 PCI adapter self test 1 Run Configuration Setup 2 Move the failing adapter to slot 1 or 2 3 Failing Adapter 4 System Board 00180700 00180800 General PCI error 1 System Board 2 PCI Card 01295085 ECC checking hardware test error 1 System Board 2 Processor 01...

Страница 142: ...for all external SCSI devices are connected correctly 3 If you have attached an external SCSI device to the server workstation make sure the external SCSI termination is set to automatic 4 The last device in each SCSI chain is terminated correctly 5 The SCSI devices are configured correctly Message Action DASD Over recommended Temperature sensor X level warning DASD bay X had over temperature cond...

Страница 143: ...condition for CPU X 1 Ambient temperature must be within normal operating specifications see Features and specifications on page 4 Message Action Fan X failure level critical fan X had a failure 1 Check connections to fan X 2 Replace fan X Fan X fault level critical fan X beyond recommended RPM range 1 Check connections to fan X 2 Replace fan X Fan X Outside Recommended Speed Action 1 Replace Fan ...

Страница 144: ...mperature level critical CPU X is over temperature 1 Ensure system is being properly cooled see Temperature checkout on page 25 2 Replace CPU X System shutoff due to CPU X under temperature level critical CPU X is under temperature 1 Ambient temperature must be within normal operating specifications see Features and specifications on page 4 2 Replace CPU X System shutoff due to DASD temperature se...

Страница 145: ...ower indicators front and rear are blinking Turn switch 1 on switch block 1 to ON If system powers on turn switch 1 on switch block 1 to OFF and replace front panel assembly If system does not power on reconfigure system to minimum operating requirements and retry If problem remains suspect the following FRUs in the order listed 1 Power supply 2 System board c Yes power indicator LEDs front and re...

Страница 146: ... a Power supply b System board If problem goes away replace removed items one at a time until failing item is found power on and reconfigure system each time Notes 1 If the problem goes away when you remove an adapter from the system and replacing that adapter does not correct the problem suspect the System Board 2 If you suspect a networking problem and all the system tests pass suspect a network...

Страница 147: ... Copyright IBM Corp 2001 139 Parts listing xSeries 330 The xSeries 330 parts listing supports Type 8674 models 11X 12X 13X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ...

Страница 148: ...d All Models 19K1351 16 Processor 133 1133 512K All Models 31P5756 17 PCI Riser Card All Models 19K1350 18 Memory 256MB 133MHz ECC All Models 10K0021 18 Memory 128MB 133MHz ECC All Models optional 10K0019 18 Memory 512MB 133MHz ECC All Models optional 10K0023 18 Memory 1GB 133MHz ECC All Models optional 33L3327 Hardware Kit All Models 00N6997 2 Port Serial Plate All Models 00N7021 Rail Assembly Al...

Страница 149: ...ls 06P6248 Cable SCSI Signal 2 Drop Model 13X 06P6237 Cable IDE Signal Model 12X 06P6236 Cable Hardfile 4 Pin Power Model 12X 13X 06P6238 60 0 GB ATA 100 Drive Model 12X optional 19K1570 Keyboard FRU No US English 37L2551 French Canadian 37L2552 LA Spanish 37L2553 Arabic 37L2555 Belgium French 37L2556 Belgium UK 37L2557 Bulgarian 37L2558 Czech 37L2559 Danish 37L2560 Dutch 37L2561 French 37L2562 Ge...

Страница 150: ...guay Uruguay Western Samoa 12J5128 Antigua Bahrain Brunei Channel Islands Cyprus Dubai Fiji Ghana China Hong Kong S A R Iraq Ireland Kenya Kuwait Malawi Malaysia Malta Nepal Nigeria Polynesia Qatar Sierra Leone Singapore Tanzania Uganda United Kingdom Yemen Zambia 12J5987 Afghanistan Algeria Andorra Angola Austria Belgium Benin Bulgaria Burkina Faso Burundi Cameroon Central African Rep Chad Czech ...

Страница 151: ...mbia Costa Rica Dominican Republic Ecuador El Salvador Guatemala Guyana Haiti Honduras Jamaica Korea South Liberia Mexico Netherlands Antilles Nicaragua Panama Peru Philippines Saudi Arabia Suriname Taiwan Trinidad West Indies Venezuela 76H4865 United States of America 6952301 110 1838574 220 36L8886 220V 15A Power cord FRU No ...

Страница 152: ...nance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 IntelliStation R Pro The IntelliStation R Pro Type 6851 parts listing supports model types 10x 11x 12x 13x 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ...

Страница 153: ...sor 133 1133 512K All Models 31P5756 17 PCI Riser Card All Models 19K1350 18 Memory 256MB 133MHz ECC All Models 10K0021 18 Memory 128MB 133MHz ECC All Models 10K0019 18 Memory 512MB 133MHz ECC All Models 10K0023 18 Memory 1GB 133MHz ECC All Models 33L3327 Mouse assembly All Models 76H6620 Keyboard Models 10x 11x 37L2551 Matrox G200 Video Adapter NTSC Models 10x 11x 25P1899 Matrox G200 Video Adapte...

Страница 154: ...els 11x 13x optional 19K1641 Hard Disk Drive Bezel Filler All Models 06P6245 Service Label All Models 06P6248 Cable IDE Signal Models 10x 12x 06P6236 Cable SCSI Signal 2 Drop Models 11x 13x 06P6237 Cable Hardfile 4 Pin Power All Models 06P6238 60 0 GB ATA 100 Drive Models 10x 12x optional 19K1570 Keyboard FRU No US English 37L2551 French Canadian 37L2552 LA Spanish 37L2553 Arabic 37L2555 Belgium F...

Страница 155: ... Canadian 37L0913 Power cord FRU No China PRC 01K9851 Japan 01K9853 Thailand 12J5120 Israel 12J5122 Bangladesh Burma India Pakistan South Africa Sri Lanka 12J5124 Chile Ethiopia Italy Libya Somalia 12J5126 Argentina Australia New Zealand Papua New Guinea Paraguay Uruguay Western Samoa 12J5128 Antigua Bahrain Brunei Channel Islands Cyprus Dubai Fiji Ghana China Hong Kong S A R Iraq Ireland Kenya Ku...

Страница 156: ...ozambique Netherlands New Caledonia Niger Norway Poland Portugal Romania Senegal Slovakia Spain Sudan Sweden Syria Togo Tunisia Turkey former USSR Vietnam former Yugoslavia Zaire Zimbabwe 55H6643 Denmark Switzerland Liechtenstein 55H6646 Bahamas Barbados Bermuda Bolivia Brazil Canada Cayman Islands Colombia Costa Rica Dominican Republic Ecuador El Salvador Guatemala Guyana Haiti Honduras Jamaica K...

Страница 157: ...s that you think are too heavy for you Do not perform any action that causes hazards to the customer or that makes the equipment unsafe Before you start the machine ensure that other service representatives and the customer s personnel are not in a hazardous position Place removed covers and other parts in a safe place away from all personnel while you are servicing the machine Keep your tool case...

Страница 158: ...cident occurs you can then operate the switch or unplug the power cord quickly Do not work alone under hazardous conditions or near equipment that has hazardous voltages Disconnect all power before Performing a mechanical inspection Working near power supplies Removing or installing main units Before you start to work on the machine unplug the power cord If you cannot unplug it ask the customer to...

Страница 159: ...dent occurs Use caution do not become a victim yourself Switch off power Send another person to get medical aid Safety inspection guide The intent of this inspection guide is to assist you in identifying potentially unsafe conditions on these products Each machine as it was designed and built had required safety items installed to protect users and service personnel from injury This guide addresse...

Страница 160: ...charge so that the machine the part the work mat and the person handling the part are all at the same charge Notes 1 Use product specific ESD procedures when they exceed the requirements noted here 2 Make sure that the ESD protective devices you use have been certified ISO 9000 as fully effective When handling ESD sensitive parts Keep the parts in protective packages until they are inserted into t...

Страница 161: ...r 1 translations for that caution statement appear in this section under statement 1 Be sure to read all caution and danger statements before performing any of the instructions Statement 1 DANGER Electrical current from power telephone and communication cables is hazardous To avoid a shock hazard Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of this...

Страница 162: ...battery as required by local ordinances or regulations Statement 3 CAUTION When laser products such as CD ROMs DVD ROM drives fiber optic devices or transmitters are installed note the following Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable parts inside the device Use of controls or adjustments or pe...

Страница 163: ...ntrol button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source Statement 10 CAUTION Do not place any object weighing more than 82 kg 180 lbs on top of rack mounted d...

Страница 164: ...odos os cabos de alimentação a tomadas elétricas corretamente instaladas e aterradas Conecte todos os equipamentos ao qual esse produto será conectado a tomadas corretamente instaladas Sempre que possível utilize apenas uma das mãos para conectar ou desconectar cabos de sinal Nunca ligue qualquer equipamento quando existir evidência de danos por fogo água ou na estrutura Desconecte cabos de alimen...

Страница 165: ...informações sobre como enviar a bateria pelo correio para a IBM Instrução 3 PRECAUCIÓN Quando produtos a laser unidades de CD ROM unidades de DVD dispositivos de fibra ítica transmissores etc estiverem instalados observe o seguinte Não remova as tampas A remoção das tampas de um produto a laser pode resultar em exposição prejudicial à radiação de laser Nenhuma peça localizada no interior do dispos...

Страница 166: ...não desligam a corrente elétrica fornecida ao dispositivo O dispositivo também pode ter mais de um cabo de alimentação Para remover toda a corrente elétrica do dispositivo assegure que todos os cabos de alimentação estejam desconectados da fonte de energia elétrica CUIDADO Instrução 10 CUIDADO Não coloque nenhum objeto com peso superior a 82 kg 180 lbs sobre dispositivos montados em rack 18 kg 37 ...

Страница 167: ...Related service information 159 ...

Страница 168: ...160 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 169: ...Related service information 161 ...

Страница 170: ...162 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 171: ...Related service information 163 ...

Страница 172: ...164 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 173: ...Related service information 165 ...

Страница 174: ...166 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 175: ...s de prise de courant correctement câblés tout équipement connecté à ce produit Lorsque cela est possible n utilisez qu une seule main pour connecter ou déconnecter les câbles d interface Ne mettez jamais un équipement sous tension en cas d incendie ou d inondation ou en présence de dommages matériels Avant de retirer les carters de l unité mettez celle ci hors tension et déconnectez ses cordons d...

Страница 176: ...ortez vous à la réglementation en vigueur Notice n 3 ATTENTION Si des produits laser sont installés tels que des unités de CD ROM ou de DVD des périphériques contenant des fibres optiques ou des émetteurs récepteurs prenez connaissance des informations suivantes N ouvrez pas ces produits pour éviter une exposition directe au rayon laser Vous ne pouvez effectuer aucune opération de maintenance à l ...

Страница 177: ...coupent pas l arrivée de courant électrique à l intérieur de la machine Il se peut que votre unité dispose de plusieurs cordons d alimentation Pour isoler totalement l unité du réseau électrique débranchez tous les cordons d alimentation des socles de prise de courant Notice n 10 ATTENTION Ne posez pas d objet dont le poids dépasse 82 kg sur les unités montées en armoire 18 kg 37 lbs 32 kg 70 5 lb...

Страница 178: ... anschließen Alle angeschlossenen Geräte ebenfalls an Schutzkontaktsteckdosen mit ordnungsgemäß geerdetem Schutzkontakt anschließen Signalkabel möglichst einhändig anschließen oder lösen Keine Geräte einschalten wenn die Gefahr einer Beschädigung durch Feuer Wasser oder andere Einflüsse besteht Die Verbindung zu den angeschlossenen Netzkabeln Telekommunikationssystemen Netzwerken und Modems ist vo...

Страница 179: ...z B CD ROM Laufwerke DVD Laufwerke Einheiten mit Glasfaserkabeln oder Transmitter installiert ist beachten Sie folgendes Das Entfernen der Abdeckungen des CD ROM Laufwerks kann zu gefährlicher Laserstrahlung führen Es befinden sich keine Teile innerhalb des CD ROM Laufwerks die vom Benutzer gewartet werden müssen Die Verkleidung des CD ROM Laufwerks nicht öffnen Steuer und Einstellelemente sowie V...

Страница 180: ...rderseite des Servers und dem Betriebsspannungsschalter am Netzteil wird die Stromversorgung für den Server nicht unterbrochen Der Server könnte auch mehr als ein Netzkabel aufweisen Um die gesamte Stromversorgung des Servers auszuschalten muß sichergestellt werden daß alle Netzkabel aus den Netzsteckdosen herausgezogen wurden Hinweis 10 ACHTUNG Keine Gegenstände die mehr als 82 kg wiegen auf Rack...

Страница 181: ...unita di terra di sicurezza Collegare qualsiasi apparecchiatura collegata a questo prodotto ad una presa elettrica correttamente cablata e munita di terra di sicurezza Quando possibile collegare o scollegare i cavi di segnale con una sola mano Non accendere qualsiasi apparecchiatura in presenza di fuoco acqua o se sono presenti danni all apparecchiatura stessa Scollegare i cavi di alimentazione i ...

Страница 182: ...la normativa in vigore D Lgs 22 del 5 2 9 e successive disposizioni nazionali e locali Avviso 3 ATTENZIONE Quando si installano prodotti laser come ad esempio le unità DVD CD ROM a fibre ottiche o trasmettitori prestare attenzione a quanto segue Non rimuovere i coperchi L apertura dei coperchi di prodotti laser può determinare l esposizione a radiazioni laser pericolose All interno delle unità non...

Страница 183: ...tazione posto sull alimentatore non disattiva la corrente elettrica fornita all unità L unità potrebbe disporre di più di un cavo di alimentazione Per disattivare la corrente elettrica dall unità accertarsi che tutti i cavi di alimentazione siano scollegati dalla sorgente di alimentazione Avviso 10 ATTENZIONE Non poggiare oggetti che pesano più di 82 kg sulla parte superiore delle unità montate in...

Страница 184: ...176 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 185: ...Related service information 177 ...

Страница 186: ...178 Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851 ...

Страница 187: ...rra y cableado correctos Conecte a tomas de alimentaciín con un cableado correcto cualquier equipo que vaya a estar conectado a este producto Si es posible utilice una sola mano cuando conecte o desconecte los cables de sent al No encienda nunca un equipo cuando haya riesgos de incendio de inundaciín o de daños estructurales Desconecte los cables de alimentaciín sistemas de telecomunicaciones rede...

Страница 188: ...la batería siguiendo los requisitos que exija el reglamento o la legislaciín local Declaración 3 PRECAUCIÓN Cuando instale productos láser como por ejemplo CD ROM unidades DVD dispositivos de fibra íptica o transmisores tenga en cuenta las advertencias siguientes No retire las cubiertas Si retira las cubiertas del producto láser puede quedar expuesto a radiaciín láser perjudicial Dentro del dispos...

Страница 189: ...n no apagan la corriente eléctrica suministrada al dispositivo Es posible también que el dispositivo tenga más de un cable de alimentaciín Para eliminar la corriente eléctrica del dispositivo asegúrese de desconectar todos los cables de alimentaciín de la fuente de alimentaciín Declaración 10 PRECAUCIÓN No coloque ningún objeto que pese más de 82 kg 180 libras encima de los dispositivos montados e...

Страница 190: ...____________________________________________________ ________________________________________________________________ 2 What would you like to see added changed or deleted in this manual ________________________________________________________________ ________________________________________________________________ 3 What is your service experience level Less than five years More than five years 4...

Страница 191: ...s are considered identical only if they 1 Are the exact machine type and models 2 Have the same BIOS level 3 Have the same adapters attachments in the same locations 4 Have the same address jumpers terminators cabling 5 Have the same software versions and levels 6 Have the same Reference Diagnostics Diskette version 7 Have the same configuration options set in the system 8 Have the same setup for ...

Страница 192: ...tium III Xeon are trademarks of Intel Corporation in the United States other countries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Java and all Java based trademarks and logos are trademarks or registered trademarks of Sun Micro...

Страница 193: ......

Страница 194: ...IBM Part Number 24P2923 File Number Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber 24P2923 0424P2923 ...

Отзывы: