Table 22. Symptom-to-FRU index (continued)
Problem indicator Component
Possible cause
Possible solutions
Amber LED is lit
and green LED is
off
Power supply
CRU
The power switch is
turned off or there
is an ac power
failure.
Replace the failed power supply
or turn on all power supply
switches.
Amber and green
LEDs are lit
Power supply
CRU
(Fault and
Power LEDs lit;
SAA lit; Direct
Current Enable
LED is not lit)
Power supply
failure
Replace the failed power supply.
Operating
environment is too
hot
Cool down the environment.
Fan failure
Replace the power supply and
fan unit CRU
All amber and
green LEDs are
slowly flashing
All drive CRUs The DS3950 controllers are going through start-of-day
process (booting up). Wait up to five minutes for the
controllers to complete the booting process. If the drive
Activity LEDs are not steady lit or momentarily flicker,
and the amber LEDs are unlit after waiting more than
six minutes, contact IBM support.
All green LEDs
are off
All CRUs
Subsystem power is
off
Check that all storage subsystem
power cables are plugged in and
the power switches are on. If
applicable, check that the main
circuit breakers for the rack are
powered on.
AC power failure
Check the main circuit breaker
and ac outlet.
Power supply
failure
Replace the power supply.
Operating
environment is too
hot
Cool down the environment.
158
IBM System Storage DS3950 Storage Subsystem: Installation, User’s, and Maintenance Guide
Summary of Contents for DS3950
Page 2: ......
Page 8: ...vi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 28: ...xxvi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 54: ...26 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 148: ...120 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 202: ...174 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 210: ...182 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 214: ...186 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 226: ...198 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 246: ...218 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 250: ...222 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 251: ......
Page 252: ...Part Number 00Y5046 Printed in USA GA32 0953 03 1P P N 00Y5046...