numeric display and the diagnostic LED.
When you turn on the power to the storage subsystem, the seven-segment LEDs
show 88 before the boot firmware starts to run. After the boot code starts, - - is
displayed.
When the storage subsystem is operating normally, the numeric display shows the
enclosure identification (enclosure ID) of the storage subsystem.
If an error has occurred and the Needs Attention LED is on, the numeric display
shows diagnostic information. The numeric display indicates the information is
diagnostic by illuminating an LED that appears as a decimal point between the
display numbers. The diagnostic LED tuns off when the numeric display shows
the storage subsystem enclosure ID. The numeric display shows various diagnostic
codes as the enclosures perform the startup process after each power cycle or reset.
After diagnostics are complete, the current storage subsystem enclosure ID is
displayed.
Diagnostic codes in the form of Lx or Hx, where x is a hexadecimal digit, indicate
storage subsystem state information. In general, these codes are displayed only
when the storage subsystem is in a non-operational state. The storage subsystem
might be non-operational due to a configuration problem (such as mismatched
types), or it might be non-operational due to hardware faults. If the storage
subsystem is non-operational due to system configuration, the storage subsystem
Needs Attention LED is off. If the storage subsystem is non-operational due to a
hardware fault, the storage subsystem Needs Attention LED is on. The definitions
for Lx diagnostic codes are listed in Table 19.
Table 19. Numeric display diagnostic codes
Value
Controller State
Description
L0
Suspended
Mismatched controller board
ID
L1
Suspended
Missing interconnect canister
L2
Suspended
Persistent memory errors
L3
Suspended
Persistent hardware errors
L4
Suspended
Persistent data protection
errors
L5
Suspended
ACS failure
L6
Suspended
Unsupported host card
L7
Suspended
Submodel identifier not set or
mismatched
L8
Suspended
Memory configuration error
Seven-segment
display
Diagnostic
LED
Figure 70. Numeric display LEDs
108
IBM System Storage DS3950 Storage Subsystem: Installation, User’s, and Maintenance Guide
Summary of Contents for DS3950
Page 2: ......
Page 8: ...vi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 28: ...xxvi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 54: ...26 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 148: ...120 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 202: ...174 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 210: ...182 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 214: ...186 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 226: ...198 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 246: ...218 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 250: ...222 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 251: ......
Page 252: ...Part Number 00Y5046 Printed in USA GA32 0953 03 1P P N 00Y5046...