Note:
Make sure that the EMC gasket does not snag on the bezel.
d.
Push the tray handle down until it latches into place.
Replacing hot-swap E-DDMs
E-DDM problems include any malfunctions that delay, interrupt, or prevent
successful I/O activity between the hosts and the E-DDMs in the storage
subsystem. This includes transmission problems between the host controllers and
the E-DDMs. This section explains how to replace a failed E-DDM.
Note:
If you want to remove an E-DDM that is not in a failed or bypass state,
always use the Storage Manager client program either to place the E-DDM
in a failed state or to place the array that is associated with the E-DDM (or
E-DDMs) in an offline state before you remove it from the storage
subsystem.
Attention:
Failure to replace the E-DDMs in their correct bays might result in loss
of data. If you are replacing an E-DDM that is part of a configured array and
logical drive, make sure that you install the replacement E-DDM in the correct bay.
Check the hardware and software documentation that is provided with your
DS3950 to see if there are restrictions regarding E-DDM configurations.
Before you begin, ensure that you wear an anti-static wrist strap.
Complete the following steps to replace a hot-swap E-DDM:
1.
Use the DS Storage Management client software to print a new storage system
profile.
2.
Determine the location of the E-DDM that you want to remove.
Attention:
Never hot-swap an E-DDM CRU when its associated green
Activity LED is flashing. Hot-swap an E-DDM CRU only when its associated
amber Fault LED is lit and not flashing.
3.
Put on antistatic protection.
4.
Remove the E-DDM CRU by doing the following:
a.
Release the latch on the E-DDM CRU by pressing on the inside of the
bottom of the tray handle, as shown by the arrow in Figure 80 on page 131.
b.
Pull the tray handle out into the open position.
c.
Pull the E-DDM CRU about 1/2 inch out of the bay and wait 70 seconds to
allow the E-DDM to properly spin down and the storage subsystem
controller to properly recognize that an E-DDM is removed from the
configuration. .
d.
Verify that there is proper identification (such as a label) on the E-DDM
CRU, and then slide it completely out of the storage subsystem.
5.
Unpack the new E-DDM. Save all packing material in case you need to return
it.
6.
Install the new E-DDM CRU by doing the following:
a.
Gently push the E-DDM CRU into the empty bay until the hinge of the tray
handle latches beneath the storage subsystem enclosure bezel.
b.
Push the tray handle down into the closed (latched) position.
7.
Check the E-DDM LEDs by doing the following:
v
When an E-DDM is ready for use, the green Activity LED lights and the
amber Fault LED is off.
132
IBM System Storage DS3950 Storage Subsystem: Installation, User’s, and Maintenance Guide
Summary of Contents for DS3950
Page 2: ......
Page 8: ...vi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 28: ...xxvi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 54: ...26 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 148: ...120 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 202: ...174 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 210: ...182 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 214: ...186 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 226: ...198 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 246: ...218 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 250: ...222 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 251: ......
Page 252: ...Part Number 00Y5046 Printed in USA GA32 0953 03 1P P N 00Y5046...