Risk of severe electrical shock
– Never turn on the power to any equipment if
there is evidence of fire, water, or structural damage. Doing so might cause severe
electrical shock
1.
After the emergency situation is over or power is restored, visually check the
storage subsystem for damage. Is there evidence of damage to any of the
storage subsystem components, cables, or equipment attached to the storage
subsystem?
v
Yes – Do not continue with this procedure. Contact your IBM service
representative for assistance. Depending on the current service agreements,
you might need to return the equipment to the factory or local service center
for repair.
v
No – Go to step 2.
Potential data loss
– Before resetting circuit breakers in the cabinet, make
sure that the storage subsystem and storage expansion enclosures power
switches are turned off. Resetting circuit breakers after an emergency
situation while the storage subsystem and storage expansion enclosure
power switches are turned on can cause potential data loss because the
configuration components might not be powered on in the correct sequence.
2.
After you check the storage subsystem for damage, make sure that the power
switches are in the off position; then plug in the DS3950 power cables, if
required.
3.
Check the system documentation of the hardware devices that you want to
turn on and determine the proper startup sequence.
Note:
Be sure to turn on all of the storage expansion enclosures and verify that
there are not any ESM or power supply and fan unit fault LEDs lit
before you turn on the DS3950.
In addition, consider the following items:
v
The storage subsystem supports simultaneous power-up of the system
components, but you must always follow the power-up sequence
listed in the “Best practices guidelines” on page 5 section during any
attended power-up procedure.
v
A storage subsystem in an optimal state recovers automatically from
an unexpected shutdown and unattended simultaneous restoration of
power to system components. After power is restored, contact IBM
technical support if any of the following conditions occur:
– The storage subsystem logical drives and subsystems do not
display in the Storage Manager graphical user interface (GUI).
– The storage subsystem logical drives and subsystems do not come
online.
– The storage subsystem logical drives and subsystems seem to be
degraded.
4.
Turn on the power to each device, based on the startup sequence.
5.
Turn on any attached disconnect devices.
6.
Turn on both of the power supply switches on the DS3950. The green LEDs on
the front and the back of the DS3950 remain lit. If other amber Fault LEDs
light, see “Solving problems” on page 155.
Chapter 4. Operating the storage subsystem
113
Summary of Contents for DS3950
Page 2: ......
Page 8: ...vi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 28: ...xxvi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 54: ...26 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 148: ...120 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 202: ...174 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 210: ...182 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 214: ...186 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 226: ...198 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 246: ...218 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 250: ...222 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 251: ......
Page 252: ...Part Number 00Y5046 Printed in USA GA32 0953 03 1P P N 00Y5046...