v
Yes -
Turn off
both
power switches on each enclosure that you intend to
connect to the power.
v
No -
Turn off
both
power switches on
all
enclosures in the storage
subsystem.
2.
Make sure that all power cords are connected. See “Cabling the ac power
supply” on page 92 for details, depending on the DS3950 configuration you
purchased.
Note:
If the power cords are not connected, turn off both power switches on all
modules in the configuration before connecting power cords or turning
on the main circuit breakers.
3.
If the main circuit breakers are turned off, turn them on.
4.
Verify that the link rate setting on the front of the storage expansion enclosure
matches the speed of the drives in the subsystem.
Attention:
You must turn on power to each attached storage expansion
enclosure before turning on power to the DS3950 storage subsystem to make
sure that the controllers recognize all drives in the configuration during the
startup process.
5.
Turn on both power switches on the back of each storage expansion enclosure
attached to the storage subsystem. While each storage expansion enclosure
powers up, the green and amber LEDs on the front and back of the storage
expansion enclosure turn on and off intermittently. Depending on your
configuration, it can take several minutes for each storage expansion enclosure
to power on.
Check the LEDs on the front and back of all the storage expansion enclosures.
Verify that no Needs Attention or enclosure ID LEDs light on any of the storage
expansion enclosures. To verify the Fibre Channel connections between the
drive expansion enclosures, make sure that no Port Bypass LEDs for
connections to other storage expansion enclosures are lit. Only the Port Bypass
LED of the ESM port that connects directly to the storage subsystem drive port
should be lit.
Note:
The drive activity LEDs will flash slowly (once every 2 seconds) until the
drive is started by the DS3950 controller.
6.
Turn on both power switches on the back of each controller in the storage
subsystem.
Depending on the number of storage expansion enclosures in the configuration,
the storage subsystem might take several minutes to power on. The battery
self-test might take an additional 15 minutes. The LEDs will flash intermittently
until the storage subsystem powers up and completes the battery self-test. The
green Battery Charging LED will flash slowly (once every 2 seconds) until the
battery is fully charged.
Before attempting any operations, wait at least five minutes for the storage
subsystem to completely power on. A storage subsystem can take up to 10
minutes to power on and up to 15 more minutes to complete its controller
battery self-test. During this time, the indicator lights on the front and back of
the module flash intermittently.
7.
Determine the status of all storage subsystems and components in the
configuration by completing the following steps:
a.
Check all LEDs on each component in the storage expansion enclosures.
Make sure that all the LEDs show normal status. For more information
96
IBM System Storage DS3950 Storage Subsystem: Installation, User’s, and Maintenance Guide
Summary of Contents for DS3950
Page 2: ......
Page 8: ...vi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 28: ...xxvi IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 54: ...26 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 148: ...120 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 202: ...174 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 210: ...182 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 214: ...186 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 226: ...198 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 246: ...218 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 250: ...222 IBM System Storage DS3950 Storage Subsystem Installation User s and Maintenance Guide...
Page 251: ......
Page 252: ...Part Number 00Y5046 Printed in USA GA32 0953 03 1P P N 00Y5046...