AC power supply and fan units
The DS3500 storage subsystem (models DS3512-C2A and DS3524-C4A) and EXP3500 storage enclosure
(models EXP3512-E2A and EXP3524-E4A) each have two removable ac power supplies. Each ac power
supply contains two fans. The four fans pull air through the drives from front to back across the drives.
The fans provide redundant cooling, which means that if one fan fails, the remaining fans continue to
provide sufficient cooling to operate the storage subsystem or storage enclosure. If one power supply is
turned off or malfunctions, the other power supply maintains electrical power to the storage subsystem
or storage enclosure. To preserve the optimal airflow, do not remove a failed power supply from the
chassis until you are ready to replace it with a new power supply.
Figure 1-9 shows the ac power supply components.
DC power supply and fan units
The DS3524 storage subsystem (model C4T) and EXP3524 storage enclosure (model E4T) each have two
removable dc power supplies. Each dc power supply contains two fans. The four fans pull air through
the drives from front to back across the drives.
The fans provide redundant cooling, which means that if one fan fails, the remaining fans continue to
provide sufficient cooling to operate the storage subsystem or storage enclosure. If one power supply is
turned off or malfunctions, the other power supply maintains electrical power to the storage subsystem
or storage enclosure. To preserve the optimal airflow, do not remove a failed power supply from the
chassis until you are ready to replace it with a new power supply.
Figure 1-10 on page 1-13 shows the dc power supply components.
Hot-swap power supplies
Filler panel
ESM
1
2
ESM
Figure 1-8. Rear view, single ESM model storage enclosure
Power
switch
Power
connector
Power
switch
Power
connector
Figure 1-9. AC power supply components
1-12
System Storage DS3500 and EXP3500: Installation, User's, and Maintenance Guide
Summary of Contents for DS3500
Page 1: ...System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide GA32 0952 01...
Page 5: ...Index X 1 Contents v...
Page 6: ...vi System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 10: ...x System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 44: ...2 6 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 94: ...3 50 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 116: ...4 22 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 164: ...6 8 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 174: ...A 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 178: ...B 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 186: ...C 8 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 190: ...X 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 191: ......
Page 192: ...Part Number 90Y8716 Printed in USA GA32 0952 01 1P P N 90Y8716...
Page 193: ...Click below to find more Mipaper at www lcis com tw Mipaper at www lcis com tw...