Solving problems in the EXP3500 storage enclosure
The following table contains troubleshooting information to help you solve some basic problems that you
might have with the EXP3500 storage enclosure.
Table 6-2. Troubleshooting information
Component
Problem indicator
Possible cause
Possible solutions
Drive
Amber fault LED lit
Drive failure
Replace the failed drive. See Chapter 5, “Replacing
components,” on page 5-1 for more information.
ESM
Board failure
Replace the failed ESM. See Chapter 5, “Replacing
components,” on page 5-1 for more information.
Front panel
General machine
fault
A status or fault LED is lit. Check for amber LEDs
on components. See “Checking the LEDs” on page
4-7.
All components
All green LEDs off
The EXP3500 is
turned off
Make sure that all power cables are connected and
that the power is on. If applicable, make sure that
the main circuit breakers for the rack are turned on.
ac or dc power
failure
Check the main circuit breaker and ac outlet (ac
models). Check the -48 V dc power source and
disconnect device (dc models).
Power-supply
failure
Replace the power supply. See Chapter 5,
“Replacing components,” on page 5-1 for more
information.
Midplane failure
Contact your IBM technical-support representative.
Drives
Amber fault LED
flashing
Drive rebuild or
identity in process
No action is required.
Power supply -
ac
Amber fault LED lit;
green dc power LED
off
Power supply
failure; power
supply turned off
If the power-supply switch is on, turn off the
power supply and then turn it on again. If the
condition remains, replace the power supply.
Power supply -
ac
Amber fault LED lit;
green ac power LED
off
No ac power to
power supply
Check the ac power cord or breaker.
v
If ac power is good at the source, replace the
power cord.
v
If the power supply has failed, replace the power
supply.
Power supply -
dc
Amber fault LED lit;
green dc power out
LED off
Power supply
failure; power
supply turned off
If the power-supply switch is on, turn off the
power supply and then turn it on again. If the
condition remains, replace the power supply.
Power supply -
dc
Amber fault LED lit;
green dc power in
LED off
No -48 V dc power
to power supply
Check the dc power cable or disconnect device.
v
If dc power is good at the source, replace the dc
power cable or the 20 A disconnect device.
v
If the dc power cable and the disconnect device
are working properly, replace the power supply.
ESM
Link fault amber LED
lit
SAS
communication
failure
1.
Reconnect the SAS cable.
2.
Replace the SAS cable.
3.
If the LED is still lit, replace either the ESM or
the controller or device into which the other end
of the SAS cable is connected.
6-6
System Storage DS3500 and EXP3500: Installation, User's, and Maintenance Guide
Summary of Contents for DS3500
Page 1: ...System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide GA32 0952 01...
Page 5: ...Index X 1 Contents v...
Page 6: ...vi System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 10: ...x System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 44: ...2 6 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 94: ...3 50 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 116: ...4 22 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 164: ...6 8 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 174: ...A 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 178: ...B 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 186: ...C 8 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 190: ...X 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 191: ......
Page 192: ...Part Number 90Y8716 Printed in USA GA32 0952 01 1P P N 90Y8716...
Page 193: ...Click below to find more Mipaper at www lcis com tw Mipaper at www lcis com tw...