The drives come preinstalled in drive trays. Install drives in the drive bays on the front of the storage
subsystem or storage enclosure. When a drive is installed, the drive and tray bay designation is set
automatically. The hardware addresses are based on the enclosure ID setting on the controller and on the
physical locations of the drives.
There are no serviceable parts in a drive assembly. If it fails, it must be replaced in its entirety (drive,
bezel, and tray). When you replace a drive, be sure to order and install the correct drive. Using an
unsupported drive causes the drive to be locked out by the controller firmware.
Attention:
1.
After you remove a drive from a bay, wait 70 seconds to allow the drive to spin down before you
replace or reseat the drive. Failure to do so might cause unpredictable results.
2.
Never hot-swap a drive when its associated green activity LED is flashing or its associated amber
fault LED is flashing. Hot-swap a drive only when its associated amber fault LED is lit continuously
or when the drive is inactive and its associated green activity LED is not flashing.
Note:
If the drive that you want to remove is not in a failed or bypass state, always use the Storage
Manager software either to place the drive in a failed state or to place the array that is associated with
the drive (or drives) in an offline state before you remove the drive from the enclosure.
Controllers
The DS3500 storage subsystem comes with one or two controllers. When the DS3500 storage subsystem
has two controllers, the controllers are hot-swappable and redundant. The controllers contain the storage
subsystem control logic, interface ports, and LEDs. Each controller contains the following ports:
v
Two 6 Gbps SAS host ports
v
One SAS drive port to connect EXP3500 storage enclosures
v
Two Ethernet ports for subsystem management
Drives 1 - 4
Drives 5 - 8
Drives 9 - 12
Figure 1-5. Right-side bezel (DS3512 and EXP3512)
1 2
3 4 5
6 7 8
9 10 11 12 13
14 15 16 17 18 19
20 21 22 23 24
Drives 1 - 24
Figure 1-6. Bottom shelf (DS3524 and EXP3524)
1-10
System Storage DS3500 and EXP3500: Installation, User's, and Maintenance Guide
Summary of Contents for DS3500
Page 1: ...System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide GA32 0952 01...
Page 5: ...Index X 1 Contents v...
Page 6: ...vi System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 10: ...x System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 44: ...2 6 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 94: ...3 50 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 116: ...4 22 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 164: ...6 8 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 174: ...A 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 178: ...B 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 186: ...C 8 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 190: ...X 4 System Storage DS3500 and EXP3500 Installation User s and Maintenance Guide...
Page 191: ......
Page 192: ...Part Number 90Y8716 Printed in USA GA32 0952 01 1P P N 90Y8716...
Page 193: ...Click below to find more Mipaper at www lcis com tw Mipaper at www lcis com tw...