Firmware updates
Attention:
Save the storage subsystem profile before you perform any controller or ESM firmware
upgrades. Save the profile and all configuration (.cfg) files to a server disk that will remain accessible in
the event of a DCS3700 storage configuration failure. Do not save these files only to a LUN in the storage
subsystem.
To ensure the optimal operation of the storage subsystem and its attached storage enclosures, the ESM
firmware, controller firmware, drive firmware, and the NVSRAM firmware must be up-to-date. Go to
http://www.ibm.com/servers/storage/support/disk/ to get the latest updates.
Always see the readme files that are included with the firmware packages for the most up-to-date
information about firmware prerequisites, firmware update instructions, download-sequence information,
and host I/O restrictions, if any. Apply the necessary updates before you configure the storage subsystem
arrays and logical drives. Subscribe to My Support for automatic notifications of firmware or Storage
Manager software updates or any important information about the DCS3700 storage subsystems (see
“Receiving product updates and support notifications” on page 5).
Attention:
Failure to observe the limitations, prerequisites, sequences, and dependencies in the readme
file might result in a loss of data access.
Unless the readme file contains special requirements for the sequence in which you upgrade firmware,
perform firmware upgrades in the following sequence:
1.
ESM firmware for the expansion enclosures
2.
Controller firmware
3.
Controller NVSRAM
4.
Drive firmware
Troubleshooting the storage subsystem
The Storage Manager software is the best way to monitor the storage subsystem, diagnose a problem,
and recover from a hardware failure. Run the Storage Manager software continuously, and frequently
check the configuration status.
To check the status of and identify a problem with the storage subsystem, complete the following steps. If
a problem has occurred, use the Storage Manager software and the LEDs on the storage subsystem to
help locate a failed component.
1.
Open the Subsystem Management window.
2.
Click the
Summary
tab, and view the status of the storage subsystem.
3.
Does any storage subsystem have a Needs Attention status?
v
Yes:
Go to step 4.
v
No:
All components are Optimal. Go to step 5.
4.
Click
Recovery Guru
on the toolbar. Perform the procedure in the Recovery Guru to correct the
problem. The Recovery Guru might direct you to replace the failed component. If so, go to step 5.
Attention:
If the fault requires you to power-off an enclosure in your storage subsystem, you might
have to cycle the power on the DCS3700 storage system and all remaining expansion enclosures that
are part of the storage subsystem. Contact your IBM technical-support representative before you
power-off any other component of the storage subsystem.
5.
Check the LEDs on the front and the rear of the storage enclosure. A green LED indicates a normal
status; an amber LED indicates a hardware fault.
6.
Is an amber LED lit?
v
Yes:
Locate and troubleshoot the failed components. See “Checking the LEDs” on page 73.
72
IBM System Storage DCS3700: Installation, User, and Maintenance Guide
Summary of Contents for DCS3700
Page 1: ...IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 2: ......
Page 3: ...IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 8: ...vi IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 12: ...x IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 18: ...xvi IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 22: ...xx IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 62: ...40 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 75: ...Figure 34 Single Expansion Enclosures Chapter 3 Cabling the DCS3700 53...
Page 88: ...66 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 150: ...128 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 168: ...146 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 178: ...156 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 180: ...158 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 188: ...166 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 198: ...176 IBM System Storage DCS3700 Installation User and Maintenance Guide...
Page 201: ......
Page 202: ...Part Number 90Y8588 Printed in USA 1P P N 90Y8588...