Memory
Note: SIMMs must be set in the Setup Utility for correct parity setting.
When removing or installing a SIMM, run the Setup Utility (and set the date
and time) to clear any XX62 errors. See “POST Error Codes” on page 2-3.
001
– Insert the Diagnostics CD into the CD-ROM Drive.
– Power-off the system unit.
– Ensure all SIMMs are seated correctly.
– Power-on the system unit.
– Note any messages, error codes, or symptoms. Disregard 164 errors
(memory size).
DID YOU RECEIVE A 201 or 203 POST ERROR?
Yes No
002
DID YOU RECEIVE A 229 ERROR?
Yes No
003
Go to Step 006 on page 2-39.
004
Note: The system board has a pluggable cache module; continue
with the following step to determine whether to replace the
cache memory module or the system board.
– Replace the system board cache memory with a known good
module.
– Replace the system board.
005
– Follow the screen instructions to run the Memory tests.
– If you cannot run the memory test or the test does not find a problem, use
the following procedure to find the failure.
– Replace each SIMM, one at a time, with a known-good SIMM of the same
size and type. For the system board, replace the DIMM, if present, with a
known-good DIMM of the same size and type.
(Step 005 continues)
2-38
Summary of Contents for Aptiva 2159
Page 1: ...Hardware Maintenance Service for Service Level A Machine Type 2159 and IBM Monitors 2159...
Page 2: ......
Page 3: ...Hardware Maintenance Service for Service Level A Machine Type 2159 and IBM Monitors 2159...
Page 22: ...xx...
Page 24: ...xxii...
Page 124: ...2 72...
Page 184: ...5 22...
Page 186: ...6 2...
Page 190: ...Assembly 2 Machine Type 2159 System Unit Interior SL A 6 7 8 5 3 12 13 4 2 9 11 10 1 7 4...
Page 193: ...Assembly 3 Diskette and Hard Disk Drives 3 1 4 4 4 2 Parts Catalog 7 7...