I/O module bay 2
I/O module bay 2 supports an optional I/O module, such as an Ethernet switch or
a pass-thru module, that connects to the two integrated Ethernet controllers in each
of the blade servers.
Note:
If you install an I/O module in I/O module bay 2, you will also need to
install an expansion card option, such as the 2/4 Port Ethernet Expansion Card, in
each blade server that will access the external Ethernet network through the switch
module in I/O module bay 2.
I/O module bays 3 and 4
I/O module bays 3 and 4 support SAS connectivity modules or SAS RAID
controller modules.
v
If you are using the RAID storage solution, you must install two SAS RAID
controller modules, one in I/O module bay 3 and one in I/O module bay 4. SAS
RAID controller modules require a SAS expansion card option in each blade
server that will access the integrated shared storage.
v
If you are using only one SAS connectivity module, install the module in I/O
module bay 3. You can install an additional SAS connectivity module in bay 4. A
SAS connectivity module requires a SAS expansion card option in each blade
server that will access the integrated shared storage.
The two bays also support Ethernet switch modules, Fibre Channel switch
modules, and pass-thru modules (optical and copper) if the storage modules are
not being used.
Important:
I/O module bays 3 and 4 must both contain the same type of switch
(either SAS connectivity modules, SAS RAID controller modules, Ethernet switch
modules, pass-thru modules, or Fibre Channel switch modules).
Power modules
The BladeCenter S system supports up to four autoranging power modules that
are capable of supporting either 110 V ac or 220 V ac.
Chapter 1. Introduction
19
Summary of Contents for 88861TU
Page 1: ...IBM BladeCenter S Type 7779 8886 Planning Guide...
Page 2: ......
Page 3: ...IBM BladeCenter S Type 7779 8886 Planning Guide...
Page 30: ...24 BladeCenter S Type 7779 8886 Planning Guide...
Page 44: ...38 BladeCenter S Type 7779 8886 Planning Guide...
Page 76: ...70 BladeCenter S Type 7779 8886 Planning Guide...
Page 118: ...112 BladeCenter S Type 7779 8886 Planning Guide...
Page 124: ...118 BladeCenter S Type 7779 8886 Planning Guide...
Page 128: ...122 BladeCenter S Type 7779 8886 Planning Guide...
Page 129: ......
Page 130: ...Part Number 60Y1614 Printed in USA 1P P N 60Y1614...