There are two LEDs on each hard disk drive:
Green
Flashing when an operation, such as a read or a write, is being performed.
Amber
Flashing when the hard disk drive is being rebuilt (fast blink) or identified
(slow blink).
Note:
When power is restored to the BladeCenter S chassis after a
complete loss of power and you have implemented the hard disk drives as
a mirrored array, the fault light will blink as the hard disk drive is being
resynchronized.
This resynchronization occurs because the blade servers are attempting to
power on before all of the storage modules and SAS connectivity modules
are powered up and available. The mirrored array is accessible during
resynchronization although performance may be slightly slower.
Solid when there is a drive failure.
Media tray
The media tray contains the DVD drive (which can be either a CD-RW/DVD-ROM
drive or a DVD/RW drive) and two USB v2.0 ports, which are shared by the blade
servers. The media tray also contains two battery backup units, which provide
backup for SAS RAID controller modules cache
Note:
The port on the side of the media tray is reserved for future use.
8
BladeCenter S Type 7779/8886: Planning Guide
Summary of Contents for 88861TU
Page 1: ...IBM BladeCenter S Type 7779 8886 Planning Guide...
Page 2: ......
Page 3: ...IBM BladeCenter S Type 7779 8886 Planning Guide...
Page 30: ...24 BladeCenter S Type 7779 8886 Planning Guide...
Page 44: ...38 BladeCenter S Type 7779 8886 Planning Guide...
Page 76: ...70 BladeCenter S Type 7779 8886 Planning Guide...
Page 118: ...112 BladeCenter S Type 7779 8886 Planning Guide...
Page 124: ...118 BladeCenter S Type 7779 8886 Planning Guide...
Page 128: ...122 BladeCenter S Type 7779 8886 Planning Guide...
Page 129: ......
Page 130: ...Part Number 60Y1614 Printed in USA 1P P N 60Y1614...