![IBM 883725U Installation Manual Download Page 79](http://html1.mh-extra.com/html/ibm/883725u/883725u_installation-manual_4125387079.webp)
Note:
When
there
is
a
reference
to
an
error
log
in
the
following
table
and
your
model
has
the
optional
Remote
Supervisor
Adapter
II
SlimLine
option
installed,
view
the
system
event
error
log;
otherwise,
view
the
POST
error
log.
The
two
error
logs
are
located
on
the
Configuration/Setup
Utility
in
the
Event/Error
logs
option.
For
more
information,
see
the
User’s
Guide
.
LED
Problem
Action
None
An
error
has
occurred
and
cannot
be
diagnosed,
or
the
ASM
processor
has
failed.
The
error
is
not
represented
by
a
Light
Path
diagnostics
LED.
Check
the
system
error
log
for
information
about
the
error.
OVER
SPEC
The
power
supplies
are
using
more
power
than
their
maximum
rating.
Replace
the
failing
power
supply,
or
remove
optional
devices
from
the
server.
PS
1
When
the
LED
is
lit,
the
power
supply
in
bay
1
has
failed.
When
the
LED
flashes,
an
invalid
power-supply
configuration
has
occurred.
If
the
power
supply
has
failed,
call
for
service.
If
a
configuration
error
has
occurred,
make
sure
that
the
power
supply
is
installed
correctly.
PS
2
When
the
LED
is
lit,
the
power
supply
in
bay
2
has
failed.
When
the
LED
flashes,
an
invalid
power-supply
configuration
has
occurred.
If
the
power
supply
has
failed,
call
for
service.
If
a
configuration
error
has
occurred,
make
sure
that
the
power
supply
is
installed
correctly.
CPU
When
the
LED
is
lit,
a
microprocessor
has
failed.
When
the
LED
flashes,
an
invalid
microprocessor
configuration
has
occurred.
If
a
lit
LED
on
the
system
board
indicates
a
problem
with
a
microprocessor,
make
sure
that
the
microprocessor
is
installed
correctly.
See
the
Option
Installation
Guide
on
the
IBM
xSeries
Documentation
CD
for
information
about
installing
a
microprocessor.
If
the
problem
remains,
call
for
service.
If
a
configuration
error
has
occurred,
make
sure
that
the
microprocessors
have
the
same
cache
size
and
type,
and
the
same
clock
speed.
Microprocessor
internal
and
external
clock
frequencies
must
be
identical.
VRM
When
the
LED
is
lit,
an
error
occurred
on
the
microprocessor
voltage
regulator
module
(VRM).
When
the
LED
flashes,
an
invalid
VRM
configuration
has
occurred.
Replace
the
VRM.
If
the
problem
remains,
call
for
service.
If
a
configuration
error
has
occurred,
make
sure
that
the
VRM
is
installed
correctly.
If
the
problem
remains,
replace
the
VRM.
CNFG
When
the
LED
flashes,
a
hardware
configuration
error
has
occurred.
Check
the
system
error
log
for
information
about
the
error.
The
Light
Path
diagnostic
LED
for
the
component
that
is
causing
the
configuration
error
also
flashes.
MEM
When
the
LED
is
on,
a
memory
error
has
occurred.
When
the
LED
flashes,
an
invalid
DIMM
configuration
has
occurred.
Replace
the
failing
DIMM,
which
is
indicated
by
the
lit
LED
on
the
system
board.
If
a
configuration
error
has
occurred,
make
sure
the
DIMMs
are
installed
correctly.
NMI
A
machine
check
error
has
occurred.
Check
the
system
error
log
for
information
about
the
error.
S
ERR
A
soft
error
has
occurred.
Check
the
system
error
log
for
information
about
the
error.
SP
The
service
processor
has
failed.
Remove
ac
power
from
the
server;
then,
reconnect
the
server
to
ac
power
and
restart
the
server.
If
the
problem
remains,
call
for
service.
DASD
A
hard
disk
drive
error
has
occurred.
Check
the
LEDs
on
the
hard
disk
drives
and
replace
the
indicated
drive.
Chapter
6.
Solving
problems
67
Summary of Contents for 883725U
Page 3: ...IBM xSeries 336 Type 8837 Installation Guide ERserver...
Page 18: ...6 IBM xSeries 336 Type 8837 Installation Guide...
Page 38: ...26 IBM xSeries 336 Type 8837 Installation Guide...
Page 46: ...34 IBM xSeries 336 Type 8837 Installation Guide...
Page 64: ...52 IBM xSeries 336 Type 8837 Installation Guide...
Page 66: ...54 IBM xSeries 336 Type 8837 Installation Guide...
Page 112: ...100 IBM xSeries 336 Type 8837 Installation Guide...
Page 113: ......
Page 114: ...Part Number 25R4613 Printed in USA 1P P N 25R4613...