Undetermined problems
You are here because the diagnostic tests did not identify
the failure, the Devices List is incorrect, or the system is
inoperative.
Notes
If you suspect a software mismatch is causing failures
(solid or intermittent), be sure to see “Configuration
conflicts” on page 20.
Check power supply. If the LEDs indicate the power
supplies are working correctly, return here and do the
following:
1. Power-off the computer.
2. Remove or disconnect the following (one at a time)
until you find the failure (power-on the computer and
reconfigure each time).
Any external devices
Surge suppressor device (on the computer)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory-Module Kits (Minimum requirement = 1
bank of 64 MB DIMMs)
Note
Minimum operating requirements vary for each
computer. For example, an IML drive in the drive
startup sequence (IML systems only).
3. Power-on the computer. If the problem remains,
suspect the following FRUs in the order listed:
System Board
Processor Board
Front Panel
Note
If the problem goes away when you remove an
adapter from the system, and replacing that adapter
does not correct the problem, suspect the system
board then the processor board(s).
198
Netfinity Server HMM
Summary of Contents for 847620U - Netfinity 3000 - 20U
Page 2: ......
Page 8: ...vi Netfinity Server HMM ...
Page 145: ...Caution Use safe lifting practices when lifting the machine IBM Netfinity 3000 Type 8476 137 ...
Page 218: ...210 Netfinity Server HMM ...
Page 238: ...230 Netfinity Server HMM ...
Page 239: ...Related service information 231 ...
Page 240: ...232 Netfinity Server HMM ...
Page 241: ...Related service information 233 ...
Page 242: ...234 Netfinity Server HMM ...
Page 255: ...Related service information 247 ...
Page 256: ...248 Netfinity Server HMM ...
Page 257: ...Related service information 249 ...
Page 269: ......
Page 270: ...IBM Part Number 19K2484 Printed in U S A S1ðL 9798 ð5 ...