Table 2. Power-supply LEDs
Power-supply LEDs
Description
Action
Notes
AC
DC
Error
Off
Off
Off
No AC power to
the server or a
problem with the
AC power source
1. Check the AC power to the server.
2. Make sure that the power cord is
connected to a functioning power
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
This is a normal
condition when no
AC power is
present.
Off
Off
On
No AC power to
the server or a
problem with the
AC power source
and the power
supply had
detected an
internal problem
1. Replace the power supply.
2. Make sure that the power cord is
connected to a functioning power
source.
This happens only
when a second
power supply is
providing power to
the server.
Off
On
Off
Faulty power
supply
Replace the power supply.
Off
On
On
Faulty power
supply
Replace the power supply.
On
Off
Off
Power supply not
fully seated,
faulty system
board, or faulty
power supply
1. Reseat the power supply.
2. If the system board error LED is off,
replace the power supply.
3. (Trained service technician only) If the
system board error LED is lit, replace
the system board.
Typically indicates
that a power supply
is not fully seated.
On
Off or
Flashing
On
Faulty power
supply
Replace the power supply.
On
On
Off
Normal operation
On
On
On
Power supply is
faulty but still
operational
Replace the power supply.
Server power features
When the server is connected to an AC power source but is not turned on, the
operating system does not run, and all core logic except for the integrated
management module (IMM) is shut down; however, the server can respond to
requests from the IMM, such as a remote request to turn on the server. The
power-on LED flashes to indicate that the server is connected to AC power but not
turned on.
Turning on the server
Approximately 20 seconds after the server is connected to AC power, the
power-control button becomes active, and one or more fans might start running to
provide cooling while the server is connected to power. You can turn on the server
and start the operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
Chapter 1. The System x3500 M3 server
19
Summary of Contents for 7380E1U
Page 1: ...IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 2: ......
Page 3: ...IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 8: ...vi IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 64: ...48 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 66: ...50 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 68: ...52 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 79: ...Chapter 2 Installing optional devices 63 ...
Page 142: ...126 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 152: ...136 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 158: ...142 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Page 159: ......
Page 160: ... Part Number 81Y6295 Printed in USA 1P P N 81Y6295 ...