Service Access Cover (Model 6C1)
1
2
3
1
Service access cover
2
Cover-release latch
3
Side latches
1. To install or remove any part other than a hot-swap hard disk drive, hot-swap power
supply, or hot-swap fan, turn off the server and all attached devices and disconnect
all external cables and power cords.
2. If you have not already done so, place the server in the service position as
described in “Placing the Model 6C1 in the Service Position” on page 35.
3. Move the cover-release lever (2) down while sliding the service access cover (1)
toward the rear of the server about 25 mm (1 inch). Lift the cover off the server and
set the cover aside.
Attention:
For proper cooling and airflow, replace the cover before turning on the
server. Operating the server for extended periods of time (over 30 minutes) with the
cover removed might damage server components.