Monitor or video problems
Use this information to diagnose and resolve monitor or video errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
The video monitor is a shared BladeCenter unit resource. First, make sure that the
video monitor is assigned to the blade server; then, see the following table and
“Solving shared BladeCenter resource problems” on page 227.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
The screen is blank.
1.
Check the function of the shared BladeCenter unit resources (see “Solving
shared BladeCenter resource problems” on page 227).
2.
Make sure that the blade server is turned on (see “Turning on the blade
server” on page 14).
3.
Make sure that the monitor is connected properly. See the documentation for
your BladeCenter unit for more information.
4.
Make sure that:
v
Damaged BIOS code is not affecting the video; see “Recovering from a UEFI
update failure” on page 223.
v
The device drivers are installed correctly.
5.
Follow the UEFI recovery procedure in “Recovering from a UEFI update
failure” on page 223).
6.
(Trained service technician only) Replace the system-board assembly (see
“Removing the system-board assembly” on page 97 and “Installing the
system-board assembly” on page 98).
The monitor has screen jitter, or
the screen image is wavy,
unreadable, rolling, or
distorted.
1.
Check the function of the shared BladeCenter unit resources (see “Solving
shared BladeCenter resource problems” on page 227).
2.
(Trained service technician only) Replace the system-board assembly (see
“Removing the system-board assembly” on page 97 and “Installing the
system-board assembly” on page 98).
Wrong characters appear on the
screen.
1.
If the wrong language is displayed, update the firmware or operating system
with the correct language in the blade server that has ownership of the
monitor.
2.
Check the function of the shared BladeCenter unit resources (see “Solving
shared BladeCenter resource problems” on page 227).
3.
(Trained service technician only) Replace the system-board assembly (see
“Removing the system-board assembly” on page 97 and “Installing the
system-board assembly” on page 98).
170
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Summary of Contents for 1911
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Page 267: ......
Page 268: ... Part Number 90Y5614 Printed in USA 1P P N 90Y5614 ...