Chapter 4. Solving Problems
95
complete, the message
Recovery complete, remove the diskette and return
boot block switch to the off position before rebooting
is displayed.
6. Remove the flash diskette from the diskette drive.
7. Turn the server off.
8. Remove the jumper on the boot-block jumper block or move it to pins 1 and 2 to
return to normal startup mode.
9. Restart the server. The system should start up normally.
Identifying problems using status LEDs
If the System Error light in the operator information panel on the front of the server is
on, one or more LEDs inside the server or on the power supplies will be on. Use the
light path diagnostics to identify the type of error that occurred.
Light path diagnostics
You can use the light path diagnostics built into your server to quickly identify the
type of system error that occurred. Your server is designed so that any LEDs that are
illuminated remain illuminated when the server shuts down as long as the AC power
source is good and the power supplies can 5V dc current to the server. This
feature helps you isolate the problem if an error causes the server to shut down. See
“Light path diagnostics table” on page 97.
Power supply LEDs
The AC and DC Power LEDs on the power supply provide status information about
the power supply.
The following table describes the AC and DC Power LEDs.
DC power
LED (green)
AC power
LED (green)
Summary of Contents for 150
Page 1: ...IBM IBM xSeries 150 User s Reference...
Page 2: ......
Page 3: ...IBM IBM xSeries 150 User s Reference...
Page 10: ...viii IBM xSeries 150 User s Reference...
Page 78: ...66 IBM xSeries 150 User s Reference...
Page 138: ...126 IBM xSeries 150 User s Reference...
Page 150: ...138 IBM xSeries 150 User s Reference...
Page 179: ......