110
IBM® xSeries 150 : User’s Reference
PCNTND-7
A Protocol Manager device error occurred.
Explanation:
The NDIS stack is not configured correctly. Action: Check and correct your
configuration.
PCNTND-8
Bad status for the Protocol Manager.
Explanation:
The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action:
Check and correct your configuration.
PCNTND-9
Cannot find the PROTOCOL.INI entry.
Explanation:
The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action:
Check and correct your configuration.
PCNTND-10
The Protocol Manager Input Output Control (IOCTL) failed.
Explanation:
The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action:
Check and correct your configuration.
PCNTND-11
Protocol Manager registration failed.
Explanation:
The NDIS stack is not configured correctly. Action: Check and correct your
configuration.
PCNTND-15
Device not found.
Explanation:
The driver cannot find an Ethernet controller in the server. Action: Verify that
the Ethernet controller is enabled. If the Ethernet controller is enabled, go to “Starting the
diagnostic programs” on page 84 to run the diagnostic programs.
PCNTND-16
PCI scan specified, device not found.
Explanation:
The driver cannot locate the Ethernet controller on the PCI bus.Action: Verify
that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to “Starting the
diagnostic programs” on page 84 to run the diagnostic programs.
PCNTND-21
The adapter failed the checksum test.
Explanation:
The driver cannot find an Ethernet controller.Action: Verify that the Ethernet
controller is enabled. If the Ethernet controller is enabled, go to “Starting the diagnostic
programs” on page 84 to run the diagnostic programs.
PCNTND-23 WARNING: PCNET IRQ found =
xx
Explanation:
The interrupt request (IRQ) setting (xx) in the PROTOCOL.INI file does not
match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI
file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in
the PCI Slot/Device Information selection of the Advanced Setup menu in the
Configuration/Setup Utility program.
PCNTND-24
WARNING: PCNET IRQ does not match PROTOCOL.INI.
Explanation:
The interrupt request (IRQ) setting in the PROTOCOL.INI file does not match
the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or
change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI
Slot/Device Information
selection of the Advanced Setup menu in the Configuration/Setup
Utility program.
PCNTND-25
PCI scan specified, PCI bus not found!
Explanation:
The driver cannot locate the PCI bus. Action: Run the diagnostic programs.
Table 19. NDIS 2.01 (OS/2) driver messages for the Ethernet controller
Summary of Contents for 150
Page 1: ...IBM IBM xSeries 150 User s Reference...
Page 2: ......
Page 3: ...IBM IBM xSeries 150 User s Reference...
Page 10: ...viii IBM xSeries 150 User s Reference...
Page 78: ...66 IBM xSeries 150 User s Reference...
Page 138: ...126 IBM xSeries 150 User s Reference...
Page 150: ...138 IBM xSeries 150 User s Reference...
Page 179: ......