Chapter 4. Solving Problems
101
Intermittent problems
Verify that:
1. All cables and cords are connected securely to the rear of the server and attached
options.
2. When the server is turned on, air is flowing from the rear of the server at the fan
grill. If there is no air flow, the fan is not working. This causes the server to
overheat and shut down.
3. Ensure that the SCSI bus and devices are configured correctly and that the last
external device in each SCSI chain is terminated correctly.
If the items above are correct, call for service.
A problem occurs only
occasionally and is difficult to
detect.
Keyboard, mouse, or pointing-
device problems.
1. Make sure that the keyboard cable is properly connected to the server.
2. Make sure that the server and the monitor are turned on.
3. Try using another keyboard.
If the items above are correct, call for service.
All or some keys on the
keyboard do not work.
The mouse or pointing device
does not work.
1. Verify that the mouse or pointing-device cable is securely connected and the
device drivers are installed correctly.
2. Try using another mouse or pointing device.
If the problem remains, call for service.
Memory problems
Verify that:
1. The memory modules are seated properly.
2. You have installed the correct type of memory.
3. If you changed the memory, you updated the memory configuration with the
Configuration/Setup Utility program.
4. All banks of memory on the DIMMs are enabled. The server might have
automatically disabled a DIMM bank when it detected a problem or a DIMM
bank could have been manually disabled.
If the above items are correct, run the memory diagnostic program. The system might
have detected a bad memory module and automatically reallocated memory to
enable you to continue to operate. If the memory tests fail, call for service or replace
the failing DIMM.
The amount of memory
displayed is less than the
amount of memory installed.
Microprocessor problems
The startup (boot) microprocessor is not working properly.
Verify that the startup microprocessor is seated properly. If it is, replace the startup
microprocessor.
If the problem remains, call for service.
The server emits a continuous
tone during POST.
Monitor problems
Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, refer to the information that comes with the monitor for adjusting and
testing instructions.
If you still cannot find the problem, call for service.
Testing the monitor.
Table 16. Troubleshooting charts
Device
Suggested action
Summary of Contents for 150
Page 1: ...IBM IBM xSeries 150 User s Reference...
Page 2: ......
Page 3: ...IBM IBM xSeries 150 User s Reference...
Page 10: ...viii IBM xSeries 150 User s Reference...
Page 78: ...66 IBM xSeries 150 User s Reference...
Page 138: ...126 IBM xSeries 150 User s Reference...
Page 150: ...138 IBM xSeries 150 User s Reference...
Page 179: ......