background image

©Copyright Lotronic 2017 

 

 

 

LASER FOR PROFESSIONAL USE ONLY 

This laser complies with the international standards EN60825-1:2014. It is 
meant 

exclusively for professional use

.  

Its installation and use should only be carried out by a skilled technician 
who is aware of the specific dangers of lasers. 
 

REMINDER OF SAFETY INSTRUCTIONS 

Lasers of class 3 and 4 are for outdoor use only.  
Inside the public area, any laser shooting towards the audience is strictly forbidden except if a safety area of 5 m 
radius is marked around the area to which the audience cannot get access.  
The area called “public area” is defined by the space of 3m above the area occupied by the audience and a width of 
2.5m around this area. The public area must be clearly identified by signs on the ground.  
Inside the public area only a scanning movement is allowed within the terms and conditions defined by the 
international technical laser safety report. 
The laser unit must be installed out of reach of the audience and at a minimum of 3m above the ground where the 
audience is present or protected by a safety perimeter of 5m radius.   
The laser unit must be installed in such a way that it can’t be moved under the effect of disruptions such as crowd 
movements, vibrations or gusts of wind.  

 
Safety Instructions

 

Please read these instructions carefully, they include important information about the installation, usage and 
maintenance of this product. 
• Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also receives 
this instruction booklet. 
• Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is 
not higher than that stated on the decal or rear panel of the fixture.  
• This product is intended for indoor use only! 
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 
• The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be 
sure that no ventilation slots are blocked. 
• Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size 
and type. 
• Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying 
handles. 
• Maximum ambient temperature (Ta) is 104° F (40°C).  Do not operate the fixture at temperatures higher than this. 
• In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by 
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the same type of spare parts. 
• Don’t connect the device to a dimmer pack. 
• Make sure the power cord is never crimped or damaged. 
• Never disconnect the power cord by pulling or tugging on the cord. 
• Avoid direct eye exposure to the light source while it is on. 
DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the 
disconnect device shall remain readily operable. 
  

GB 

Summary of Contents for SCAN500RGB

Page 1: ...c 2017 1 L LA AS SE ER R W WI IT TH H D DM MX X I IL LD DA A Ref SCAN500RGB SCAN1100RGB SCAN2000RGB SCAN1100PINK USER MANUAL MODE D EMPLOI Imported from China by LOTRONIC SA Avenue Z nobe Gramme 9 148...

Page 2: ...ce If you sell the unit to another user be sure that he also receives this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecti...

Page 3: ...e that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and able to support a weight of 10 times...

Page 4: ...peration description Set the function overview FUNCTION key At every short press on the FUNC button following actions are active INDR DMX 5 CH simplified DMX mode you can set the DMX address via the U...

Page 5: ...t automatically enter 3 Scene playback only play a scene This mode for the temporary mode restart laser will not automatically enter Slave mode divided into the following two slave modes 1 DMX slave m...

Page 6: ...CHANNEL DMX value DESCRIPTION CH 1 On off power 0 OFF 1 99 ON 100 199 AUTO 200 254 retain 255 Pattern A closed light pattern B output light CH2 Out of bounds and pattern size 0 49 Out of bounds 50 99...

Page 7: ...7 Y zooming 2 128 159 Y zooming 3 160 191 Y zooming 4 192 223 Y zooming 5 224 255 Y zooming 6 CH11 Force Segmentation Color 0 Patterns original colors 1 255 The length of the segmented colors CH12 Pat...

Page 8: ...larger the value the smaller the projection range Table 2 PATTERN B Note Table 2 CH18 CH34 pattern B s channel function except for special instructions only control the pattern B pattern A is not con...

Page 9: ...Vertical moving 0 63 Manual moving 64 95 vertical 1 96 127 vertical 2 128 159 vertical 3 160 191 vertical 4 192 223 vertical 5 224 255 vertical 6 CH26 X axis Horizontal zooming 0 63 Manual X zooming...

Page 10: ...ern A is voice activated the CH32 action will also become a voice activated state 0 31 Forward hand drawn gradually 32 63 Reverse manual drawing 64 95 Extended drawing 96 127 Contraction drawing 128 1...

Page 11: ...s whether the digital display sequence is selected when the mixed mode of the built in mode is used Note SEL status flag indicates whether the sequence is selected DR indicates the X mirror setting DR...

Page 12: ...to a recycling centre Ask your local authorities or your dealer about the way to proceed LASER A USAGE EXCLUSIVEMENT PROFESSIONNEL Ce laser est conforme aux normes EN60825 1 2014 il est usage exclusi...

Page 13: ...de dysfonctionnement arr tez imm diatement l appareil N essayez jamais de r parer l appareil par vous m me Une r paration mal faite peut entra ner des dommages et des dysfonctionnements Contactez un s...

Page 14: ...d un reset et sont ensuite op rationnels 5 Commandez les appareils avec une console DMX Description Fonction de r glage Chaque pression courte sur le bouton FUNC effectue les actions suivantes INDR DM...

Page 15: ...naux RESERVE AUX PROFESSIONNELS AVERTIS Order 1 Professional DMX mode is available to the experienced lighting engineers who are professional in DMX Table 1 PATTERN A Note Table 1 CH1 Ch17 pattern A s...

Page 16: ...Horizontal 4 192 223 Horizontal 5 224 255 Horizontal 6 CH8 Vertical moving 0 63 Manual moving 64 95 vertical 1 96 127 vertical 2 128 159 vertical 3 160 191 vertical 4 192 223 vertical 5 224 255 vertic...

Page 17: ...l drawing 64 95 Extended drawing 96 127 Contraction drawing 128 159 Both ends are zoomed at the same time 160 191 Head and tail were zooming 192 223 Walking drawing 224 255 Turn over drawing CH16 Auxi...

Page 18: ...ue exceeds the number of patterns the system uses the largest number CH22 Patterns zooming 0 No zooming 1 31 Zooming 1 32 63 Zooming 2 64 95 Zooming3 96 127 Zooming4 128 159 Zooming 5 160 191 Zooming...

Page 19: ...Array control 0 63 Normal blanking control 64 127 Patterns without blanking flyback line banking 128 159 Patterns and line without blanking 160 191 Pattern A anchored in an array pattern of pattern B...

Page 20: ...sur les touches pour entrer l adresse DMX en mode de r glage vous povuez s lectioner la distance de projection lors du r glage de l angle de projection En mode lecture de sc ne appuyez pour ajuster l...

Reviews: