Version: 23.01
As of: 01/2023
Page
49
from
119
Step 7B:
Affix the TRAPEZOIDAL CLAMP to the outer roofing with self drilling screws
•
When using the self drilling screws, two screws are placed per TRAPEZOIDAL CLAMP. In this process, make sure you
screw carefully to maintain static properties. The self drilling screws are tightened until the seal swells out a little.
•
The enclosed self drilling screws 5,5x25 are approved for a sheet metal or aluminum thickness of 0.5 mm to 1.5 mm.
Attention!
Pre-drilling of the trapezoidal sheet is not permitted.
Step 8A:
Insert and affix the transverse securing clamp with blind rivets
•
The transverse securing clamps are affixed next to the trapezoidal clamp on the left and right with a clearance of
approximately 20 mm.
•
The gap of 20 mm must remain free due to the floating bearing. Otherwise, damage may occur.
•
There must be a minimum of two transverse securing clamp per string (11.90 m).
Attention!
Mount additional transverse securing clamps on roofs that are particularly exposed to wind.
Figure 71 Apply the screw
Figure 72 Trapezoidal clamp screwed
Figure 73 Insert transverse securing clamps
Figure 74 Drilling transverse securing clamps