Version: 23.01
As of: 01/2023
Page
16
from
119
Description
L = (MB + 20 mm) × n + 48 mm
Support rail=
(MB + 20 mm) × number of modules per row + 48 mm
MB
Module width
MH
Module hight
n
Number of modules
A
TF50+ / TF50+m / TF60 support rail
B
Roof hook
C
Middle clamp
D
Outside clamp
E
max. 400 mm
X
X
–
selected fixing interval
(dimensioned using PV-Manager software)
Z
Please observe module manufacturer specifications
Figure 4 Layout of the IBC TopFix 200 pitched roof mounting system