Manual
ibaBM-DDCS
42
Issue 1.11
Note
Beginning with ibaPDA version 6.35, the diagnose data is pre-defined by ibaPDA.
In ibaPDA version 6.34 or older, the user had to manually enter the diagnose data.
In this case, the number of analog and digital signals had to be entered in the
General
tab and the diagnose values with address and designation had to be manually entered
in the
Analog
and
Digital
tabs.
For an easier configuration, pre-configured diagnose modules for the most important
diagnostic data were available on the DVD “iba Software & Manuals”, which is included
in delivery. The modules could be imported in the I/O Manager:
- Module 290: diagnostic counter for data set telegrams drive 1 – 16
- Module 291: diagnostic counter for data set telegrams drive 17 – 32
- Module 299: general diagnostic values, counter, error displays
9.1.6
Module type “Data set telegram counters”
Here you can see the basic settings for the module:
Figure 26 : Data set telegram counters –
General
tab
Basic settings
Module type
Display of the module type, cannot be modified
Locked
True: No changes possible. Only authorized users can unlock modules.
False: Any user can make changes
Enabled
True: Data acquisition is enabled for this module
False: Data acquisition is not enabled for this module
Name
Name of the module
Module no.
Logical number of the module
Timebase
Acquisition timebase used for this module