![IBA ibaBM-DDCS Manual Download Page 37](http://html1.mh-extra.com/html/iba/ibabm-ddcs/ibabm-ddcs_manual_3210872037.webp)
ibaBM-DDCS
Manual
Issue 1.11
37
Figure 18: Data set browser
Depending on whether the selected type is analog or digital, the signal will appear on the
Analog
or
Digital
tab. Node number (slave), data set number and index are entered
automatically.
Figure 19: Overview of the data set signals
Complete control words, status words and fault words can be captured as analog value
and itemized by 16 bit-decoders in ibaPDA.
Note
Make sure, that a signal is not requested twice. In case of duplicate signals ibaPDA
displays an error message when starting the acquisition.