background image

Target Position
Target Position No.
Control Signal

PLC

Current Position
Completed Position No.
Status Signal

Gateway

Unit

+24V

RCP6S

Actuator

Hub Unit

Communication with Fieldbus

Target Position
Positioning Width
Speed
Acceleration/Deceleration
Push %
Control Signal

PLC

Current Position
Current Value 
(Command Value)
Current Speed
(Command Value)
Alarm Code
Status Signal

+24V

RCP6S

Actuator

Gateway

Unit

Hub Unit

Communication with Fieldbus

Teaching Pendant 

(to be purchased separately)

PC software 

3) RCP6S connecting cable
    CB-RCP6S-PWBIO□□□
    (Enclosed in Actuator)

System I/O Connector

(Top Surface)

Axis Power Supply Connector

Axis Control Connector

(Bottom Surface)

Control Power Supply Connector

Motor Power Supply Connector

Drive Cutoff Connector

SIO Connector

1) Connection
    Cable between
    GW and Hub
    CB-RCP6S-RLY□□□
    (Prepare separately)

(to be purchased separately) 

Fieldbus

Connecting

Dummy Plug
DP-5 

(Note1)

 

Host System (master unit) 
PLC etc.…Please prepare separately)

Gateway 

Unit 

Emergency Stop Circuit

Drive Cutoff Circuit 

Control/Drive 
Power Supply 
(24V DC   

…Please prepare 
separately) 

It is also available to 
connecting with miniUSB.

Hub Unit 

(MAX. 4 units)

RCP6S Actuator

(MAX. 16 units) 

RCP6S Connector

Hub Power Supply
Connector

Hub Control Connector

Current Position

Gateway Unit 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Hub Unit 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Operation Mode Selected 

This controller are available to select from 6 types of operation modes.   
The settings are to be established with Gateway Parameter Setting Tool. 

Operation 

Mode 

Contents 

Overview 

Simple Direct 
Mode

 

The target position can be indicated 
directly by inputting a value. Also, 
monitoring of the current position is 
available in 0.01mm unit. 
Those other than the target position are 
to be indicated in the position table, and 
the setting can be done for 768 points at 
maximum. 

Positioner 1 
Mode 

The 768 points of position data can be 
registered at the maximum and is able 
to stop at the registered positions. Also, 
monitoring of the current position is 
available in 0.01mm unit. 

 

Direct Indication 
Mode 
 
 

The target position, speed 
acceleration/deceleration and pressing 
current limit can be indicated with 
inputting a number. 
As well as monitoring of the current 
position in 0.01mm unit, monitoring of 
current speed and command current is 
also available. 
* For those except for CC-Link, the 

maximum number of the connectable 
axes should be eight axes when a hub 
unit is used and two when not used. 

 

Positioner 2 
Mode 

This is the operation mode of the 
position data of 768 points at maximum 
set in the position table. The monitoring 
of the current position is not available 
This mode is that the transferred data is 
reduced from Positioner 1 Mode. 

 

Operation 

Mode 

Contents 

Overview 

Positioner 3 
Mode 

This is the operation mode of the 
position data of 256 points at maximum 
set in the position table. The 
monitoring of the current position is not 
available 
This is the mode to control with the 
minimized number of signals to 
perform the positioning operation by 
reducing the amount of sent and 
received data from Positioner 2 Mode. 

 

Positioner 5 
Mode 

This is the operation mode of the 
position data of 16 points at maximum 
set in the position table. 
It is a mode that enabled to monitor the 
current position in 0.1mm unit by 
number of position table from 
Positioner 2 Mode. 

 

 

Wiring Diagram 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

Note 1 

For RCM-P6GWG, in case a teaching tool is not connected to SIO connector, have the enclosed dummy plug 
plugged (DP-5) in the connector.

 

 
 
 
 
 
Connection Cable 

1. Connection to RCP6S Gateway Unit and Hub Unit 

 
 
 
 
 
 
 
 

2. Connection to RCP6S Gateway Unit and RCP6S 

 
 
 
 
 

3. Connection to RCP6S Hub unit and RCP6S 

 
 
 
 

* Extension Cable is utilize these holes if necessary. 

 

□□□ in the cable model code should be the cable length. e.g.) 030=3m, -RB should be included in the model code when it is the 
robot cable. 
The maximum length should be 10m between the gateway and hub unit. 
The maximum length should be 20m from the gateway unit to RCP6S regardless of a hub unit is used or not used. 
 
1, 3, 5 and 10m are prepared in standard for 1) 
1, 3, and 5m are prepared in standard for 2) and 4) 
 

Power Supply and Emergency Stop Circuit 

The following diagram shows an example of how the emergency stop switch for the teaching pendant may be included in the 
emergency stop circuit you may construct. 

RCP6S Actuator or RCP6S 
Gateway Controllers
Built in Drive Cutoff Circuit
(MAX.16 units)

Teaching Tool
Operation 
Stop Switch

System I/O
Connector

SIO 
Connector

Teaching 
Tool Connection 
Detection Circuit
(Contact opens 
when connected)

Dedicated
Operation
Stop 
Circuit

Wiring 
Conducted
at Delivery

Operation Stop 
Detection Times

Hub Unit

Gateway Unit

24V DC
Power Supply

Motor Power Supply

Control Power Supply

 

 

Example for shutting off motor power supply externally at emergency stop input. 

 

RCP6S

Gateway Unit

Emergency Stop
Detection Circuit

System I/O
Connector

SIO Connector

Axis Control

Connector

(C)

Axis Power

Supply Connector

(M)

(MAX. 16 units) 

Control Power Supply Connector

Motor Power Supply Connector

Use a hub unit if necessary.

Four units at the maximum of RCP6S 
actuators and/or RCP6S Gateway 
controllers can be connected to 
one unit of the hub unit.

In case a hub unit is not to be 
connected, connect an actuator 
or a controller for RCP6S GW to 
the axis control connector (C).

(Note 1)

(Note 3)

(Note 2)

(Note 2)

(Note 2)

(Note 2)

(Note 2)

(Note 4)

Drive Cutoff Connector

Emergency
Stop
Release
Switch

Emergency
Stop Switch

Emergency Stop Switch
on the Teaching Pendunt

Hub
Unit 1

Hub
Unit 4

Hub
Unit 3

Hub
Unit 2

RCP6S Actuator or 
RCP6S Gateway 
Controllers

 

 

Note 1  RCM-P6GW  : When there is nothing plugged in the SIO connector, S1 and S2 are short-circuited inside the controller. 
 

RCM-P6GWG : When there is nothing plugged in the SIO connector, S1 and S2 are not short-circuited.   

  To make them short-circuited, have the enclosed dummy plug DP-5 plugged in the SIO connector. 

Note 2  When the motor power must be disconnected externally for safety category compliance, apply a safety rated relay 

between MPI-AXIS

 and MPO-AXIS

.  

Note 3  The rating for the emergency stop signal (EMG-) to turn ON/OFF at contact CR1 is 24V DC and 10mA or less. 
Note 4  For CR1, select the one with coil current 0.1A or less. 

 

(Note)  When supplying the power by turning ON/OFF the 24V DC, keep the 0V being connected and have the +24V 

supplied/disconnected (cut one side only).

 

RCP6S Actuator 

4) RCP6S Extension Cable* 

CB-RCP6S-PWBIO□□□-JY1 

3) RCP6S Connection Cable 

CB-RCP6S-PWBIO□□□ 

 

Gateway Unit 

 

Axis  Power  Supply     

  Connector 

 

 

Axis Control Connector

 

  Hub Unit 

 

 

RCP6S Connector 

RCP6S Actuator 

4) RCP6S Extension Cable* 

CB-RCP6S-PWBIO□□□-JY1 

3) RCP6S Connection Cable 

CB-RCP6S-PWBIO□□□

 

 

Hub Unit 

 

Hub Power Supply 
Connector 

Hub Control 
Connector

 

1) GW-hub Connection Cable 

CB-RCP6S-RLY□□□ 

2) GW-hub Extension Cable* 

CB-RCP6S-RLY□□□-JY1 

  Gateway Unit 

 

Axis  Power  Supply     

  Connector 

 

 

Axis Control Connector 

 

10mm 

or more 

10mm 

or more 

10mm 

or more 

100mm or more 

100mm or more 

100mm or more 

100mm or more 

10mm or more 

10mm or more 

10mm 

  or more 

10mm 

  or more 

10mm 

or more 

Caution: 

Make sure to turn the power to the gateway unit OFF when inserting or removing the connector that 

connects the PC software or gateway unit to the controller.   

Inserting or removing the connector while the power is turned ON causes a gateway unit failure. 

It is available that RCP6S Gateway controller is 
connected instead of connecting a RCP6S actuator 
and connects an actuator of RCP2 to 6, RCA2 or 
RCD.   

Refer to the Instruction Manual and First Step Guide of the 
RCP6S Gateway Controllers for details. 