Status Indicator LED 

LED1

SYS

LED2

AUTO

LED3

EMG

LED4

T. ERR

LED5

C. ERR

Starting Procedures 

When using this product for the first time, make sure to avoid mistakes and incorrect wiring by referring to 
the procedure below. “PC” stated in this section means “PC software”. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Status Indicator LED 

Built-in Controller

 

 
 
 
 
 
 
 
 
 
 
 
 

Gateway Unit 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Hub Unit 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan

TEL +81-54-364-5105  FAX +81-54-364-2589

website: www.iai-robot.co.jp/

Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany

TEL 06196-88950  FAX 06196-889524

SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China

TEL 021-6448-4753  FAX 021-6448-3992

website: www.iai-robot.com

Technical Support available in USA, Europe and China

Head Office: 2690 W. 237th Street, Torrance, CA 90505

TEL (310) 891-6015  FAX (310) 891-0815

Chicago Office: 110 East State Parkway, Schaumburg, IL 60173

TEL(847) 908-1400  FAX (847) 908-1399

TEL (678) 354-9470  FAX (678) 354-9471

website: www.intelligentactuator.com

Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066

825 PhairojKijja Tower 7th Floor, Bangna-Trad RD., Bangna, Bangna, Bangkok 10260, Thailand

TEL +66-2-361-4458  FAX +66-2-361-4456

website:www.iai-gmbh.de

website:www.iai-robot.co.th

 

Symbol 

LED 

Display Color and Operation Status 

LED1 

SYS 

System Status 

Ready (Green Illuminating), 
Alarm (Red Illuminating) 

LED2 

AUTO 

Operation Mode (AUTO/MANU) Status 

Automatic Operation (AUTO) Mode 
(Green Illuminating) 

LED3 

EMG 

Emergency Stop (EMG) Status 

Emergency Stop (EMG) (Red Illuminating) 

LED4 

T. ERR 

Bus Communication Error inside Controller 

T. ERR (Orange Illuminating) 

LED5 

C. ERR 

Fieldbus Network Communication Error 

C. ERR (Orange Illuminating) 

Symbol 

LED 

Display Color and Operation Status 

LED1 

AX3 STS 

LED2 

AX2 STS 

LED3 

AX1 STS 

LED4 

AX0 STS 

Axis No.0 to 3 Status 

Servo OFF (OFF) 
Servo ON (Green Illuminating) 
Automatic Servo OFF (Green Flashing) 
Alarm, Emergency Stop (Red Illuminating) 
Communication Error (Red Flashing) 

LED5 

SYS 

Hub Unit System Status 

Ready (Green Illuminating) 
Standby for Communication Establishment 
(Green Flashing) 
Control/Motor Power Voltage Drop 
(Red Illuminating) 

↓ Yes 

 

No → 

 

Check of Packed Items 

Are all the delivered items present? 

Contact your local IAI distributor. 

Installation and Wiring 

1) Install actuators, gateway unit, hub unit and RCP6S Gateway Controller (if necessary). 
2) Do the wirings to the actuator built-in controller, gateway unit, hub unit and RCP6S Gateway Controller (if it is installed). 

Important Check Item 

• Is frame ground (FG) connected? 

• Has the noise countermeasure been taken? 

↓ 

 

Power Supply and Alarm Check 

Connect the PC software, set the operation mode setting switch to “MANU” side and turn the power ON. 
Select [Teaching Mode 1 Safety Speed Activated / Prohibit PIO Startup] in the PC software. 

↓ 

↓ Yes 

 

No → 

 

Check Item 

1) Is SYS in the status display LED lamps on the gateway unit turned ON in 

green? 

2) Is SYS in the status display LED lamps on the hub unit turned ON in green? 
3) Are all the status display LED lamps for each built-in controller and RCP6S 

Gateway Controller turned OFF? 

If an alarm is generated (LED: 
Red Illuminating), check the 
details of the alarm in the PC 
software to have a 
counteraction. 

↓ 

 

Initial Setting 

Have the fieldbus and operation mode setting conducted with the gateway parameter setting tool. 

Servo ON 

Turn the servo ON for all the connected axes by operating the PC. 

Caution:  Please perform this process with the actuator away from the mechanical end or interfering objects as 

much as possible. Move the actuator away from interfering surroundings. It may generate an alarm if the 
actuator hit the mechanical end or interfering objects when the servo is turned ON.   
The slider may get slightly dropped by self-weight if servo ON and OFF is repeatedly performed at the 
same position. Be careful not to pinch the hand or damage the work. 

↓ 

 

↓ Yes 

 

No → 

 

Check Item 

1) Is the status display LED lamp for the actuator (controller) in which the 

servo is turned ON turned ON in green? 

2) Is the status LED lamp for the applicable axis number of the hub unit 

turned ON in green? 

If an alarm is generated (LED: Red 
Illuminating), check the detail of the 
alarm on the PC and have an 
appropriate treatment. 

↓ 

 

↓ Yes 

 

No → 

 

Check of Safety Circuit 

Does the emergency stop circuit (drive cutoff circuit) work properly and 
turn the servo OFF? 

Check the emergency stop circuit. 

Setting of Position Data [Except for direct numerical specification mode] 

Set the position

 (*)

, velocity and acceleration/deceleration in each position table. 

* Setting is unnecessary in simple direct mode 

↓ 

 

Test Run Adjustment 1 

1) Cancel the emergency stop, do not put a work piece on, set to low speed and check the operation with commands from 

the PC. 

2) Put on a work piece, set to the automatic operation speed, and then check the operation with the command from the PC.

 

↓ Yes

 

No → 

 

Check Item 

Any vibration or abnormal noise? 

Check if there is any problem with the installation of the actuator and 
the condition of the actuator use exceeds the ranges of the rated 
values. Adjust the servo if necessary. 

↓ 

 

Test Run Adjustment 2 

Output an operation command from the host (such as PLC) to check by the system operation. 

Establish Link

 

to Fieldbus 

1) Assign RCP6S GW as the host controller [Refer to the instruction manual of the master unit]. 
2) Put the operation mode setting switch on the front panel to AUTO side, and reboot the power. 
3) Once the link with the master unit is established, turn ON MON Signal in the gateway control signals. 

(While MON Signal is ON, control from fieldbus is available.) 

↓ 

 

Status of LED 

Operation Status 

Operation status 

OFF 

Servo OFF 

Alarm (Operation Cancellation 
Level or more) 

Red Illuminating 

In the Emergency Stop 

Red Flashing 

During Crash Detection 

Green Illuminating 

Servo ON 

Green Flashing 

Motor Driving Power Supply OFF

 

Orange Illuminating 

In initializing process when the 
power is turned on 

 

Manual No.: ME0350-3B

 