8. SCON-C
5.3.2 DIP Switch Settings
The DIP switches are used to set the following items:
(1) Node address
(2) Baud rate
(Note) Turn off the controller power before setting the DIP switches.
(1) Setting the node address (MAC ID)
Set the node address (MAC ID) using a hexadecimal value according to the table below.
1: ON 0: OFF
s
e
h
c
ti
w
s
P
I
D
Node address
(MAC ID)
NA5
NA4
NA3
NA2
NA1
NA0
0
0
0
0
0
0
0
1
0
0
0
0
0
1
2
0
0
0
0
1
0
3
0
0
0
0
1
1
...
...
...
...
...
...
...
60
1
1
1
1
0
0
61
1
1
1
1
0
1
62
1
1
1
1
1
0
63
1
1
1
1
1
1
(Note) The node address corresponds to the remote I/O address in the PLC. (For details, refer to the
operation manual for the PLC.)
(2) Setting the baud rate
Set the baud rate according to the table below.
1: ON 0: OFF
DIP switches
Baud rate
DR1
DR0
125 kbps
0
0
250 kbps
0
1
500 kbps
1
0
Setting prohibited
1
1
8.3.2