47
3. XSEL-R(A)/S(A)/R(A)X/S(A)X/R(A)XD/S(A)XD
35
Reference
Port numbers are assigned to bit addresses in the PLC in units of 16 points, starting from the
channel corresponding to the node address set with the DIP switches.
(This does not apply if a configurator is used to assign port numbers.)
(Input) (Output)
(Input)
Port No.
(Output)
Port No.
Node address
Node address
(NN) CH and (MM) CH as indicated above represent PLC channel addresses corresponding
to node address nn.
As for nn, nn+1, nn+2, etc., bit addresses corresponding to each node address are occupied
in accordance with the numbers of I/O points used. Accordingly, exercise caution to prevent
node address duplication.
(2) Example for when using DeviceNet and I/O Board 1 together
It is how to establish the setting when using DeviceNet to 256 points of each input and output from the top
of the extended I/O ports and assigning the I/O board (48 points for each input and output) to the standard
I/O ports.
* The figure shown below is XSEL-R/S series. The setting should be the same for XSEL-RA/SA series.
(Except for I/O Parameter No. 225)
Extended Input Ports No.1000 to 1255
Extended Output Ports No.4000 to 4255
(DeviceNet board)
Standard Input Port No.0 to 47
Standard Output Port No.300 to 347
(I/O board)
•
I/O Parameters
No.
Parameter name
Default
(Reference) Input Range Unit
Remarks
1 I/O Port Allocation Type
1
0 to 1
0
0:Fixed Allocation
1:Automatic Allocation
•
Reference 1
Priority of I/O Port Assignment when
automatically assigned
Port Number
(No.0 to 299/No.300 to 599)
1) Network I/F Module 1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the
continuously mounted range from
mounting board
•
Reference 2
Priority of extension I/O ports at automatic
assignment
Port Number
(No.1000 to 3999/No.4000 to 6999)
1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net
* 2) and 3) are for XSEL-R/S Series only
2 Standard I/O Fix-Allocated
Input Port Start No.
0
-1 to 299
0
0+ (Multiples of 8)
[Ineffective when -1 is selected]
3 Standard I/O Fix-Allocated
Output Port Start No.
300
-1
300 to 599
300 300+ (Multiples of 8)
[Ineffective when -1 is selected]