3. XSEL-R(A)/S(A)/R(A)X/S(A)X/R(A)XD/S(A)XD
34
2.6 I/O Port Numbers for X-SEL
The table below lists the standard I/O port numbers for X-SEL controllers.
On X-SEL controllers, port numbers and function assignments can be changed using I/O parameters. (For
details, refer to the “Operation Manual for X-SEL Controller.”)
Port No.
Function
Port No.
Function
000
Program start
300
Alarm output
001
General-purpose input
301
Ready output
002
General-purpose input
302
Emergency stop output
003
General-purpose input
303
General-purpose output
004
General-purpose input
304
General-purpose output
005
General-purpose input
305
General-purpose output
006
General-purpose input
306
General-purpose output
007
Program specification (PRG No. 1)
307
General-purpose output
008
Program specification (PRG No. 2)
308
General-purpose output
009
Program specification (PRG No. 4)
309
General-purpose output
010
Program specification (PRG No. 8)
310
General-purpose output
011
Program specification (PRG No. 10)
311
General-purpose output
012
Program specification (PRG No. 20)
312
General-purpose output
013
Program specification (PRG No. 40)
313
General-purpose output
014
General-purpose input
314
General-purpose output
015
General-purpose input
315
General-purpose output
Input
Output
(Note) The numbers of I/O ports are as follows:
If DeviceNet and expansion I/O boards are used together, pay attention to the numbers of I/O
ports.
Inputs: 000 to 299 (maximum of 300 points)
Outputs: 300 to 599 (maximum of 300 points)
[1] Network Setting Check
•
For XSEL-R/S Series
Confirm that the 2nd digit of I/O Parameter No.225 Network I/F Module Control setting is showing “2”
(DeviceNet).
No.
Parameter name
Default
Input Range
Unit
Remarks
225 Network I/F Module
Control
2*
20H to 2FH
─
bits 4-7 (2nd digit):
Network I/F Module 2 types
0:Not Mounted
1:CC-Link
2:DeviceNet
3:PROFIBUS
•
For XSEL-RA/SA Series
Confirm that the 3rd digit of I/O Parameter No.225 Network I/F Module Control setting is showing “2”
(DeviceNet).
No.
Parameter name
Default
Input Range
Unit
Remarks
225 Network I/F Module
Control
2**
200H to 2FFH
─
bits 8-15 (3rd and 4th digit):
Network I/F Module 2type
0:Not Mounted
1:CC-Link
2:DeviceNet
3:PROFIBUS
[2] I/O Port Assignment Classification Setting
I/O Parameter No.1
Set I/O Port Assignment Classification
No.
Parameter name
Default
Input Range
Unit
Remarks
1
I/O Port Assignment
Classification Setting
(Note)
1
0 to 1
─
0: Fixed Allocation
1: Automatic Allocation
•
Reference 1
Priority of I/O Port Assignment when
automatically assigned
Port Number
(No.0 to 299/No.300 to 599)
1) Network I/F Module1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the
continuously mounted range from
mounting board
•
Reference 2
Priority of extension I/O ports at automatic
assignment
Port Number
(No.1000 to 3999/No.4000 to 6999)
1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net
* 2) and 3) are for XSEL-R/S Series only
Note If the automatic assignment is selected, the input port is assigned to an extension input port area
(No.1000 to 3999). The output port is assigned to an extension output port area (No.4000 to 6999).
If the fixed assignment is selected, the user will manually assign the input standard input port area
(No.0 to 299) or extension input port area (No.1000 to 3999). For the output port, the user will
manually assign the output standard output port area (No.300 to 599) or the extension output port
area (No.4000 to 6999).