64
/
3. Operation
No
Name
Initial Value
Setting Range
Remarks
19
Absolute Battery Retention
Time
2
0 to 3
Set the standard for the absolute data storage time.
Parameter
No.19 Setting
Encoder Max. Rotation
Speed [rpm]
Reference
for Battery
Retention
Time
(reference)
[day]
When the
connected
actuator is a
model other
than
RCA2-***N;
When the
connected
actuator is
RCA2-***N;
0
100
75
20
1
200
150
15
2
400
300
10
3
800
600
5
20
Position Data Change Password
0000
0000 to 9999
When “0000” is set, the password input is not required.
(Note 1) Please refer to the next section if the servo-motor gain adjustment is required.