33
/
2. Wiring
(2) PIO Pattern and Signal Assignment
Pattern
0
1
2
3
4
5
Point-to-Point
Movement
(Standard)
Point-to-Point
Movement
(Movement
Speed Setting)
Point-to-Point
Movement
(Target Position
Setting Change)
3-Point
Movement
(2-Input)
3-Point
Movement
(3-Input)
Point-to-Point
Reciprocating
Movement
(Continuous
Reciprocating
Operation)
Pin
No.
Cable
Color
Input/
Output
Single
Double
Single
Double
Single
Double
-
Double
-
1
BR
COM
24V
24V
24V
24V
24V
24V
2
RD
COM
0V
0V
0V
0V
0V
0V
3
OR
I
N
0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ST0
ASTR
4
YW
1
*
STP
ST1
(Note 1)
*
STP
ST1
(Note 1)
*
STP
ST1
(Note 1)
ST1
(Note 1)
ST1
(Note 1)
*
STP
5
GN
2
RES
SPDC (RES)
(Note 2)
CN1 (RES)
(Note 2)
RES
ST2(RES)
(Note 2)
RES
6
BL
3
/SON
/SON
/SON
/SON
/SON
/SON
7
PL
O
U
T
0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
LS0/PE0
8
GY
1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
LS1/PE1
9
WT
2
HEND/SV
HEND/SV
HEND/SV
LS2/PE2
LS2/PE2
HEND/SV
10
BK
3
*
ALM/SV
*
ALM/SV
*
ALM/SV
*
ALM/SV
*
ALM/SV
*
ALM/SV
(Note 1) : It is invalid before home-return operation.
(Note 2) : The description in the brackets shows the condition before the home return operation.
(Note 3) : *STP and *ALM are the signals that are negative logic.
(Reference) Signal of Active Low
Signal with “*” expresses the signal of active low. A signal of active low is a signal that the input signal
is processed when it is turned off, output signal is ordinary on while the power is on, and turns off when
the signal is output.
Summary of Contents for ASEP