2.
ACON-C/CG, PCON-C/CG
47
(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)
Address
Bit
Symbol
Function
Details
b5
b4
-
Unavailable
-
b3
INC
Incremental Command:
Absolute position commands are issued when this signal is OFF,
and incremental position commands are issued when the signal is
ON.
2.6.7
(24)
b2
DIR
Pressing direction specification:
“OFF” for the direction reducing the positioning band from the
target position
“ON” for the direction adding the positioning band to the target
position
2.6.7
(22)
b1
PUSH
Pressing specification :
Positioning operation is performed when this signal is OFF, and
pressing operation is performed when the signal is ON.
2.6.7
(21)
Control
signal 1
b0
-
Unavailable
-
b15
BKRL
Forced brake release: When it is turned ON, the brake is released
2.6.7
(18)
b14
RMOD
Operating mode selector:
The AUTO mode is selected when this signal is OFF, and the
MANU mode is selected when the signal is ON.
2.6.7
(19)
b13
b12
b11
b10
b9
-
Unavailable
-
b8
JOG+
+Jog: “ON” for Movement in the Opposite Direction of Home
2.6.7
(13)
b7
JOG-
-Jog: “ON” for Movement in the Home Direction
2.7.7 (13)
b6
JVEL
Jog-speed/inch-distance switching:
The values set in parameter No. 26, “Jog speed” and parameter
No. 48, “Inch distance” are used when this signal is OFF, and the
values set in parameter No. 47, “Jog speed 2” and parameter No.
49, “Inch distance 2” are used when the signal is ON.
2.6.7
(14)
b5
JISL
Jog/inch switching:
Jog operation is performed when this signal is OFF, and inch
operation is performed when the signal is ON.
2.6.7
(15)
b4
SON
Servo ON command: The servo turns ON when this signal turns
ON.
2.6.7 (5)
b3
RES
Reset: A reset is performed when this signal turns ON.
2.6.7 (4)
b2
STP
Pause: A pause command is issued when this signal turns ON.
2.6.7
(11)
b1
HOME
Home return: A home-return command is issued when this signal
turns ON.
2.6.7 (6)
PLC
outp
ut
Control
signal 2
b0
DSTR
Positioning start:
A move command is issued when this signal turns ON.
2.6.7 (8)