3. SCON-CA/CF
A
94
x
PCON-CA/CFA output
o
PLC input side (* “n” indicates the first input address of each axis.)
DO on the PCON-CA/CFA side and output data register
Remote I/O mode Position/simplified
direct value mode
Half direct value
mode
Full direct value
mode
Remote I/O mode
2
PLC input
area
(bytes)
Number of
occupied bytes: 2
Number of
occupied bytes: 8
Number of
occupied bytes: 16
Number of
occupied bytes: 32
Number of
occupied bytes: 12
n, n+1
Port No.0 to 15
Port No.0 to 15
n+2, n+3
Current position
Current position
Current position
Occupied area
n+4, n+5
Completed
position No.
(simple alarm ID)
n+6, n+7
Status Signal
Command current Command current Current position
n+8, n+9
n+10, n+11
Current speed
Current speed
Command current
n+12, n+13
Alarm code
Alarm code
n+14, n+15
Status signal
n+16, n+17
n+18, n+19
Occupied area
n+20, n+21
n+22, n+23
Total moving count
n+24, n+25
n+26, n+27
Total moving
distance
n+28, n+29
Status Signal 1
n+30, n+31
Status signal 2
(Note) The Occupied area shows the area to be occupied with the operation mode setting.
Therefore, this area cannot be used for any other purpose. Also, exercise caution to avoid node address
duplication.