3. SCON-CA/CF
A
98
Parameter No. 25 setting
512-point mode
Electromagnetic valve mode 1
Electromagnetic valve mode 2
3
4
5
Category Port No. Symbol
Signal name
Symbol
Signal name
Symbol
Signal name
0
PC1
ST0
Start position 0
ST0
Start position 0
1
PC2
ST1
Start position 1
ST1
Start position 1
2
PC4
ST2
Start position 2
ST2
Start position 2
3
PC8
ST3
Start position 3
-
4
PC16
ST4
Start position 4
-
5
PC32
ST5
Start position 5
-
6
PC64
ST6
Start position 6
-
7
PC128
-
-
8
PC256
Command position No.
-
Unavailable
-
Unavailable
9
BKRL Forced brake release
BKRL
Forced brake release
BKRL Forced brake release
10
RMOD
Operating mode
selector
RMOD
Operating mode
selector
RMOD
Operating mode
selector
11
HOME
Home return
HOME
Home return
-
12
*STP
Pause
*STP
Pause
-
13
CSTR
Positioning start
-
Unavailable
-
Unavailable
14
RES
Reset
RES
Reset
RES
Reset
PLC output
o
PCON-
CA/CFA
input
15
SON
Servo ON command
SON
Servo ON command
SON
Servo ON command
0
PM1
PE0
Position 0 complete
LS0
Retracting end
movement command 0
1
PM2
PE1
Position 1 complete
LS1
Retracting end
movement command 1
2
PM4
PE2
Position 2 complete
LS2
Retracting end
movement command 2
3
PM8
PE3
Position 3 complete
-
4
PM16
PE4
Position 4 complete
-
5
PM32
PE5
Position 5 complete
-
6
PM64
PE6
Position 6 complete
-
Unavailable
7
PM128
ZONE1
Zone 1
ZONE1
Zone 1
8
PM256
Completed position
No.
PZONE/
ZONE2
Position zone/
Zone2
PZONE/
ZONE2
Position zone/
Zone2
9
RMDS Operation mode status RMDS Operation mode status RMDS Operation mode status
10
HEND
Home return
completion
HEND
Home return
completion
HEND
Home return
completion
11
PEND Positioning completion
signal
PEND Positioning completion
signal
-
Unavailable
12
SV
Operation preparation
end
SV
Operation preparation
end
SV
Operation preparation
end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM
Alarm
*ALM
Alarm
*ALM
Alarm
PCON-
CA/CFA
output
o
PLC input
15
LOAD/
TRQS/
*ALML
Load output judgment/
torque level/
Light error status
LOAD/
TRQS/
*ALML
Load output judgment/
torque level/
Light error status
*ALML
Light error status
The symbol with a * mark shows the ON signal in normal condition.
The signal described as “Unavailable” is not controlled. (ON/OFF is undefined.)