If coaxial cable installation is acceptable, no additional hardware is required as the daVinci camera has BNC video output
and Annexxus 301/304 encoders accept BNC video inputs.
Important
When installing PTZ, remember the address
of the camera ID, which is set with a dip
switch.
After hardware installation, Annexxus 301/304 IP address must be changed. Once the new IP address is assigned, connect
to the Annexxus module through the Internet Explorer or through SRX-Pro/iP-Pro Server, open Annexxus setup and con-
figure the RS485 section under PTZ tab:
Note
PTZ tab is only available for Annexxus 301
and Annexxus 304 models.
1. Select the Channel number (BNC number on Annexxus module), where the PTZ cameras is connected
2. Set the Baud Rate to
9600
3. Set the PTZ Type to
i3 SD
4. Enter the PTZ Address (Dip-switch configured camera ID)
5. Click
Save
to save the PTZ settings
Consult the image below for more information.